Americana Building Products .
Optional Sheet B - Page 17
Aluma-Vent Installation Guide
OPTIONAL COLUMN INSTALLATION
Complete these steps after Step 11 of the standard instructions.
STEP B1
Measure the distance from the bottom of the front
runner (C) to the top of the mounting surface. Trim
column (R) to the required length.
NOTE: When measuring for column height, take into
account the added height of brackets (P) and (Q). The
brackets will add approximately 3/8” to the overall
column height when installed.
STEP B2
Insert upper column bracket (P) and (2) column
mounting brackets (Q) in the legs of column (R),
tapping with a rubber mallet if necessary.
Attach the brackets using #8 x 3/4” screws (AA).
B1