Location Requirements
Site location
Select a location near the center of the water piping
system. The water heater must be installed indoors and
in a vertical position on a level surface.
The water heater should be located in an area not subject
to freezing temperatures. Water heaters located in
unconditioned spaces (i.e., attics, basements, etc.) may
require the water piping and drain piping to be insulated
to protect against freezing. The drain and controls must
be easily accessible for operation and service.
Do not use this water heater in conjunction with a spa
or hot tub.
Note:
Local codes and requirements in your area may
require the installation of your water heater to be
accomplished in a way such that the bottom element is
elevated from the floor at least 18 inches.
4
Note: The water heater shall be located so it is not subject
to physical damage by moving vehicles or area flooding.
FIGURE 1
RESIDENTIAL GARAGE
INSTALLATION
VEHICLE
STOP
DRAIN
DRAIN
PAN
Electrical Requirements
If you lack the necessary skills required to properly install
the electrical wiring to this water heater, do not proceed
but have a qualified electrician perform the installation.
When making the electrical connections, always make
sure:
·
The electrical supply has the proper overload fuse
or breaker protection.
·
Wire sizes and connections comply with all
applicable codes.
·
Wiring enclosed in approved conduit (if required
by local codes).
·
The water heater and electrical supply are properly
grounded.
Important:
The water heater should be located in an
area where leakage of the tank or connections will not
result in damage to the area adjacent to the water heater
or to lower floors of the structure. Due to the normal
corrosive action of water, the tank will begin to leak after
an extended period of time. It is recommended that a
suitable drain pan be installed under the water heater
as shown below. This pan is to protect the property from
damage which may occur from normal condensate
formation on the tank or leaks in the tank and pipe
connections. The pan must limit the water level to a
maximum depth of 2-1/2 inches and be two inches wider
than the heater and piped to an adequate drain. Locate
the water heater near a suitable indoor drain. Outside
drains are subject to freezing temperatures which can
obstruct the drain line. The piping should be at least 3/4
ID and pitched for proper drainage.
Under no circumstance will the manufacturer be held
liable for any water damage in connection with this
water heater.
2 1/2 MAX
PIPE TO
ADEQUATE
DRAIN
AT LEAST 2 INCHES GREATER
THAN THE DIAMETER OF THE
WATER HEATER.
State of California
Note:
The water heater must be braced, anchored, or
strapped to avoid moving during an earthquake. Contact
local utilities for code requirements in your area or call
1-800-999-9515
and request instructions.
WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
WARNING
Fire Hazard
Use proper size solid copper
wire.
Use a UL approved strain relief.
Connect ground wire to green
ground screw.
Failure to do so can result in
death, fire, or electrical shock.