17
Wiring
If local codes permit, the water heater may
be connected to electric service with the
power cord provided (DO NOT use an
extension cord). A grounded receptacle is
required.
If local codes do not permit the use of
cord connections, a 120 V, 50/60 Hz
power supply, with suitable disconnecting
means, must be connected to the black and
white leads in the heater control enclosure.
A knock-out hole is provided to permit use
of conduit or metal-clad cable connectors.
The maximum current draw is
approximately 5.0 amps.
The water heater must be electrically
grounded in accordance with local
codes, or, in the absence of local codes,
in accordance with latest edition of the
National Electric Code ANSI/NFPA No.
70. Refer to the figures below for water
heater internal wiring.
NOTE: It is not recommended that this
unit be installed on a GFCI circuit.
CAUTION! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING!
1
H
H
N
N
PRESSURE
SWITCH
TEMPERATURE
SWITCH
SPARK
P1
P3
P2
E1
GND
120
PILOT
ELECTRODE
ASSY
PS
TS
TS1
TS2
FV
MOT
1
2
3
4
5
1
2
3
1
1
2
SCHEMATIC
CONNECTION DIAGRAM
W
V 4460E C
ONTR
OL
N
H
G
120 VAC
INDUCER
AX5008
3 x 2 CONNECTOR
BL
R
Y
W
BK
G
5
4
3
2
1
<
>
BK = BLACK
BL = BLUE
G = GREEN
R = RED
W = WHITE
Y = YELLOW
1
2
W
W
TS2
BK
BK
TS1
FV
1
2
3
120
NEUT
GR
OUND
120
VA
C