Residential Gas
NRGSS01110 May 2011R
Inlet and outlet connections: 3/4” male
Circulation loop connections: 3/4” female
90% THERMAL EFFICIENCY POWER VENT
CODES AND STANDARDS
• Design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3 - CSA 4.3 Standards
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1
MODEL
NUMBER
BTU
INPUT
PER
HOUR
GALLONS
OR
LITRES
FIRST HOUR
DELIVERY
GALLONS
OR
LITRES
RECOVERY
GALLONS
OR
LITRES
90°F/50°C RISE
DIMENSIONS
INCHES/CENTIMETERS
SHIPPING
WEIGHT
LBS/KG
A
B
C
D
E
F
G
H
J
K
VG6250T76NV
76,000
50
127
92
70-5/8
68-1/4
52
21
9-1/8
12
22
8
15-3/4
27
210
189
481
92
179
173
132
53
23
30
56
20
40
68
95
(B)
* INSTALL IN ACCORDANCE WITH LOCAL CODES
TOP VIEW
ANODE
(J)
(H)
(K)
HOT
COLD
(A)
(C)
(G)
(F)
(D)
(E)
DIAMETER
SIDE INLET
THERMOSTAT
DRAIN
VALVE
T & P VALVE
SIDE OUTLET
OUTLET
(L)
(L)
INLET
FRONT VIEW
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard. Heaters
shall meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992. The interior
of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a corrosion-resistant lining; polymer linings are not acceptable.
Each tank shall be furnished with an internal powered anode for cathodic protection. The unit must be equipped with a combination gas control thermostat and
non-reset type ECO. A corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted and insulated
with a non-CFC foam to reduce standby heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure.