Residential Gas 

NRGSS01110   May 2011R

Inlet and outlet connections: 3/4” male
Circulation loop connections: 3/4” female

90% THERMAL EFFICIENCY POWER VENT

CODES AND STANDARDS

•  Design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3 - CSA 4.3 Standards
•  Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1

MODEL

NUMBER

BTU

INPUT

PER 

HOUR

GALLONS

OR

LITRES

FIRST HOUR 

DELIVERY 

GALLONS

OR

LITRES

RECOVERY

GALLONS

OR

LITRES

90°F/50°C RISE

DIMENSIONS

INCHES/CENTIMETERS

SHIPPING 

WEIGHT

LBS/KG

A

B

C

D

E

F

G

H

J

K

VG6250T76NV

76,000

50

127

92

70-5/8

68-1/4

52

21

9-1/8

12

22

8

15-3/4

27

210

189

481

92

179

173

132

53

23

30

56

20

40

68

95

(B)

* INSTALL IN ACCORDANCE WITH LOCAL CODES

TOP VIEW

ANODE

(J)

(H)

(K)

HOT

COLD

(A)

(C)

(G)

(F)

(D)

(E)

DIAMETER

SIDE INLET

THERMOSTAT

DRAIN
VALVE

T & P VALVE

SIDE OUTLET

OUTLET

(L)

(L)

INLET

FRONT VIEW

Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank 
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated 
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.  Heaters  
shall meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992. The interior 
of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F,  forming a corrosion-resistant lining; polymer linings are not acceptable.  
Each tank shall be furnished with an internal powered anode for cathodic protection.  The unit must be equipped with a combination gas control thermostat and 
non-reset type ECO.  A corrosion-resistant drain valve shall be provided on the front of each unit.  The tank shall be totally encased in a steel jacket, painted and insulated 
with a non-CFC foam to reduce standby heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure.    