General Maintenance

American Time digital clocks require minimal maintenance.  Cleaning should be done with 

nothing more than a microfiber towel, moistened with water or a mild alcohol solution.  No 

abrasive materials should be used to clean the clock, as it will result in scratching of the 

case or lens.

Avoid contact with the internal components of the clock when unpacking or preparing 

for installation, or if the clock is disconnected after installation.  Contact with the internal 

components when the clock is not grounded can result in electrostatic discharge, which 

could damage the clock.

Installation

The flush-mount digital clock is designed to be mounted into a wall cavity, similar to a single 
or double gang box. Ensure that installation conforms to the National Electrical Code and 
local wiring codes.
NOTE:  If installing the clock to be used with a Timer Control Station, the clock and TCS 
must be no more than 30-ft apart. 

CAUTION: Electric Shock Hazard! Ensure that NO electrical power is present on any 
wire before installation.

1. Remove the four sheet metal screws 
(A) that hold the cover assembly (B) 
and enclosure base (C) together. Be 
sure to keep the sheet metal screws for 
reassembly.
2. Mount the enclosure base (C) into the 
wall by attaching the side of the back 
box to a stud. Opening is 12.5" x 7.4" x 
3.629".

If you are installing a Timer Control 
Station, proceed to Step 3.  To finish 
clock installation without a Timer Control 
Station, proceed to Step 6.

3. Pull the wiring from the Timer Control Station (D) through the knockouts in the enclosure. 
4. Connect the Timer Control Station wiring to the provided terminal plugs.  See wiring detail 
in the ATSTCS documentation for detailed wiring information.
5. Connect the terminal plug(s) to the terminal blocks on the clock as described in the 
ATSTCS documentation.

Specifications

SSIQ

Weight

6.5 lbs (3 kg)

Box Dimensions

12.4375" x 7.375" x 3.625" WxHxD (31.5 x 18.7 x 9.2 

Faceplate Dimensions

13.5" x 8.5" WxH (34.3 x 21.6 cm)

Line Voltage

24, 120, or 220VAC

Code Blue Current

3.0mA maximum at 12-30VAC/VDC

Operating Temperature

30°-104°F (0°-40°C)

Humidity

95% relative humidity at 86°F (30° C) maximum, non-

condensing

Display Modes

12-hour or 24-hour, set by master controller

Accuracy 

±1 second

Certifications

Electromagnetic Emissions 

EN 55032:2012/AC:2013 Class B 

FCC 15.107:2018 Class B 
FCC 15.109:2018 Class B 

Power Consumption (red)

24V

120V

220V

SSIQ, 2.5" 

6-digit

281mA

78mA

70mA

SSIQ, 4" 

4-digit

212mA

62mA

60mA