DSY261RSxE Owner's Manual

Specifications

GENERAL
Weight:

  ..............................Digital Clock/Timer    ............................... 4.0 lb.

 

 ...............................ATSTCS Control Station ........................... 0.27 lb.

External Dimensions:

 .........Digital Clock/Timer    ............................... 6.1"h x 12"w x 3.5"deep 

 

 

ATSTCS Control Station ........................... 4.63"h X 4.56"w X 1.25"deep

SPECIFICATIONS
ELECTRICAL
Power Requirements

 (Digital Clock/Timer only):

Line Voltage:

  ..................................................................................... DSY261RS

A

E and DSY261RS

P

E -120vac 60Hz

  

 

DSY261RS

B

E - 24vac 60Hz

  

 

DSY261RS

K

E - 220vac 60Hz

  

 

DSY261RS

K

E

50H

 - 220vac 50Hz

Note: Voltage is set at factory. See above part number suffix for reference.

Battery:

...............................................................................................  9vdc Rechargeable Ni-Cad Battery

Battery Charger:

 ................................................................................  9vdc Direct Current source with 

 

 

 

 current limiting resistor. 

Maximum Current 

(Digital Clock/Timer only):  .................................... 120vac 60Hz - 130mA (max), 101mA (avg)

 

 

 

24vac 60Hz - 

 

 

 

220vac 60Hz - 

 

 

 

220vac 50Hz - 

Memory Retention on Loss of Line Voltage:

 .....................................  4 hours with fully charged battery

Distance of ATSTCS from Digital Clock/Timer:

 .................................  30-ft maximum with 22 AWG stranded wire 

 

 ...............................................................................................  with  minimum 

1

/

32

" thick insulation

Clock Circuits:

  ...................................................................................  3.0mA. max. @ 24vac/120vac

Code Blue Circuits:

 ............................................................................  3.0mA. max. @ 12vac/vdc-30vac/vdc

ENVIRONMENTAL
Ambient Operating Range:

 ................................................................ 10°C to 49°C (50°F to 120°F)

Recommended Storage Temperature:

 ..............................................  -30°C to 45°C (-22°F to 113°F) 

 

 

 

 

 ............................................................................................... for six months maximum

Humidity:

 ............................................................................................  85 %RH at 30°C (86°F)

OPERATION
Modes Available:

 ................12 hour or 24-hour non-system clock

 

 

12 hour secondary clock

 

   

Incrementing timer with programmable preset value and start/stop capability

 

 

Decrementing timer with programmable preset value and start/stop capability

 

 

Code Blue incrementing timer

Accuracy:

  .............................................................................with line voltage applied - line synchronous

 

 

 

with line voltage not applied - ± 0.005 % at 25°C

Indications:

 ........................Digital Clock/Timer .....................hours and minutes - 2.3", bright red, seven segment LED’s

 

 

 

hours and minutes are separated by a colon  

 

 

 

 

 

seconds - 1", bright red, seven segment LED’s

  

ATSTCS Control Station ..............2 second audible alarm

Summary of Contents for DSY261RSxE

Page 1: ...Installation and Operation Manual Part H004825 Rev 1 August 2015 DSY261RSxE Digital Clock Elapsed Time Indicator with Code Blue...

Page 2: ...ade with energized parts Electrostatic Sensitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of t...

Page 3: ...lation Instructions 8 DSY261RSxE Installation Instructions 8 ATSTCS Installation Instructions 9 Operation 10 Power Up 10 Setting Time 10 Setting the Up Counter Preset Time 10 Up Counter Elapsed Time O...

Page 4: ...nformation regarding the Manufacturer s warranty contact the Original Purchaser OWNER S MANUAL The owner s manual does not purport to cover all the details or variations in the equipment described nor...

Page 5: ...ith fully charged battery Distance of ATSTCS from Digital Clock Timer 30 ft maximum with 22 AWG stranded wire with minimum 1 32 thick insulation Clock Circuits 3 0mA max 24vac 120vac Code Blue Circuit...

Page 6: ...s an up or down counting elapsed timer with an optional Code Blue trigger The elapsed timers can be started stopped resumed and reset Both timer modes have a programmable preset value When the timer r...

Page 7: ...e up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This position is used to choose down counting elapsed timer mode Start Stop Increment Switch Th...

Page 8: ...e 120vac 60 Hz DSY261RSAE and DSA261RSPE 24vac 60 Hz DSY261RSBE 220vac 60Hz DSY261RSKE 220vac 50Hz DSY261RSKE50H w Pull the ten wires from the clock to the control station Keep these ten wires separat...

Page 9: ...interconnecting field wires into the double gang box v Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock Timer to the appropriate wires of the Control Station See...

Page 10: ...lashing Press the INCREMENT switch until the until the desired minutes are shown and then press ENTER Press the INCREMENT switch again to set the desired seconds and then press ENTER The display will...

Page 11: ...osition v Set the SET RUN switch to the SET position The hours digits will be flashing w Using the INCREMENT switch set the desired hours for the preset time then press ENTER The minutes digits will n...

Page 12: ...n be used as a correctable synchronous secondary clock Simply connect it to a 3 wire synchronous master clock system For secondary clock wiring see diagram in Appendix 1 It will run free between corre...

Page 13: ...cannot be restarted from the switch panel To reset the clock back to normal operation the RUN SET switch must be set to the SET position momentarily and then returned to the RUN position All other fun...

Page 14: ...terminals initiates a Code Blue If the Code Blue contact opens and closes again before the Digital Clock Timer is reset back to normal operation the Code Blue timer will start over from 00 00 00 If a...

Page 15: ...enon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the operator remove AC power from the Digital Clock Ti...

Page 16: ...ation For use with 3 Wire Clocks Appendix 1 START STOP RESET INCREMENT ENTER RUN SET UP DOWN CLOCK Common white Correct red Gnd green Digital Clock Timer Clock Power AC voltage and frequency P N depen...

Page 17: ...Push INCREMENT to change Push ENTER Clock displays flashing minutes digits Push INCREMENT to change Push ENTER Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows...

Reviews: