H22
© 2008 AS America Inc.
TOWN SQUARE
®
6' x 42"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
41-3/4"
(1060mm)
26-3/4
(679mm)
C/L OF DRAIN OUTLET
OUTLINE OF
SKID RESISTANT
SURFACE
71-1/2"
(1816mm)
35-3/4"
(908mm)
13-1/4"
(337mm)
4"
(102mm)
3"
(76mm)
FLOOR CUTOUT
5" X 15"
(127 X 381mm)
OUTLINE OF CUTOUT
70" X 40-1/4"
(1778 X 1022mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
INTEGRAL
FITTING DECK
2-1/4" X 14"
(57 X 356mm)
ON/OFF
SWITCH
LEVELING STRINGER
(NOT FOR SUPPORT)
1-1/2" N.P.T. THREADS
2"
(51mm)
3-1/4"
(83mm)
C/L OF
OVERFLOW
20"
(508mm)
22"
(559mm)
ROUGH
FLOOR
INTEGRAL
FEET
SUPPORT
1-1/2" O.D.TAILPIECE
5/8"
(16mm)
3"
(76mm)
PUMP
3/4"
(19mm)
JETS (8)
EDGE OF
FLOOR
CUTOUT
SUCTION
PUMP
SAFE-T-
HEATER
REMOVABLE
BLANK
41-3/4"
(1060mm)
26-3/4
(679mm)
C/L OF DRAIN OUTLET
OUTLINE OF
SKID RESISTANT
SURFACE
71-1/2"
(1816mm)
35-3/4"
(908mm)
13-1/4"
(337mm)
4"
(102mm)
3"
(76mm)
FLOOR CUTOUT
5" X 15"
(127 X 381mm)
OUTLINE OF CUTOUT
70" X 40-1/4"
(1778 X 1022mm)
INTEGRAL
FITTING DECK
2-1/4" X 14"
(57 X 356mm)
LEVELING STRINGER
(NOT FOR SUPPORT)
1-1/2" N.P.T. THREADS
2"
(51mm)
3-1/4"
(83mm)
C/L OF
OVERFLOW
20"
(508mm)
22"
(559mm)
ROUGH
FLOOR
INTEGRAL
FEET
SUPPORT
1-1/2" O.D.TAILPIECE
5/8"
(16mm)
3"
(76mm)
3/4"
(19mm)
EDGE OF
FLOOR
CUTOUT
GENERAL SPECIFICATIONS FOR 2742 WHIRLPOOL
71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)
115 Lbs. (52 Kg.)
690 Lbs. (313 Kg.)
69 Gal. (261 L)
60 Gal. (227 L)
41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)
14-1/4 In. (362mm)
33 Lbs./Sq.Ft. (163 Kgs./Sq.m)
27.8
55.7
2.1 HP, 14.4 AMPS ,120V.
WHIRLPOOL PUMP
WHIRLPOOL ELECTRICAL SPECIFICATIONS
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
GENERAL SPECIFICATIONS FOR 2742 BATHING POOL
71-1/2 x 41-3/4 x 22 In.
(1816 x 1060 x 559mm)
115 Lbs. (52 Kg.)
690 Lbs. (313 Kg.)
41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)
14-1/4 In. (362mm)
33 Lbs./Sq.Ft. (163 Kgs./Sq.m)
27.8
55.7
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA TYPE INSTALLATION. SUMP OF
BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIALS BY OTHERS.
●
IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING SYSTEM
PIPING AND DRAIN OVERFLOW. MOUNTING HOLES DRILLED BY INSTALLER.
■
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT:
Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 / CSA
Certified. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.
Rev. 2/08