background image

10

3

5

5/16'' MIN.

MOUNTING SURFACE

11

11

10

11

1

3

Push TUBING (4) ends into VALVE (5) side outlets. Insert VALVES (5)
into mounting holes from underside of ledge.

Install LOCKNUTS (1) and RUBBER WASHERS (3) onto valve shanks.

Place RUBBER RING (11) into DECK ADAPTERS (10) and thread onto
valves until snug against internal stop.

Tighten LOCKNUT (1) to secure VALVE (5) position.

Slide FERRULE (13) and COUPLING NUT (14) to outlet of VALVE (5) and tighten
COUPLING NUT (14) firmly.

Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of
right VALVE using appropriate connector.

VALVE ASSEMBLY

HOT

COLD

13

5

14

8

7

9

9a

6

14

13

4

5

10

MOUNTING

LEDGE

DECK ADAPTER

4

INSTALL HANDLES

1

2

3

4

5

6

7

10

Figure B

Figure A

Figure D

Figure C

4

5

6

10

5

10

8

Turn VALVE to OFF position.

Figure A: Install STEM ADAPTERS (7) onto VALVE STEMS (8).

Figure B: With colored side up, place FRICTION RING (6) over DECK ADAPTER (10). Loosely screw FRICTION NUT (5)
onto DECK ADAPTER (10). Do not tighten. Align flats on FRICTION NUT (5) with RIBS (9) in HANDLE BASE (4).

Figure C: Screw HANDLE BASE (4) with FRICTION NUT (5) onto DECK ADAPTER (10) until snug against mounting
surface and aligned properly. 

Figure D: Install LEVER HANDLE (3) onto HANDLE ADAPTER (7) and align. Check alignment, if not satisfactory remove
and align. Insert HANDLE SCREW (2) and tighten. Press in INDEX BUTTON (1).

9

4

FLATS

ALIGNED

.        3 F W     

FOR FITTING

LESS SPRAY

Press TEE (6) onto SPOUT SHANK (7) making certain that the O-RING (8) is
properly seated on SHANK (7). Push COUPLING (9 or 9a) into TEE (6) and
attach to SPOUT SHANK (7) and tighten. 

Note: For product with Hand

Shower, COUPLING (9) is tightened using a 10mm (3/8”)
Hex Wrench.