      INSTALL SUPPLY ELBOW
ASSEMBLY & CONTROL BOX; 
Fig. 7 and Fig. 7a

1.  

Install HOSE CLAMP 

(22)

 onto SPOUT HOSE 

(15)

.    

  Install SPOUT HOSE 

(15)

 onto ELBOW NIPPLE 

(23)

.   

  Fully tighten HOSE CLAMP 

(22) 

to secure SPOUT  

 

 HOSE 

(15)

 to ELBOW ASSEMBLY 

(24).

 

Fig. 7. 

2.

 Using the ANCHORS 

(25)

 and SCREWS 

(26) 

supplied, 

 attach 

ELBOW 

ASSEMBLY 

(24)

 to finished wall, covering   

  the hole in wall. 

Fig. 7.

3.

  Remove CONTROL BOX COVER 

(27). 

Feed

    EXTENSION CABLES 

(5b)

 THROUGH GROMMET 

(28)

    in back of CONTROL BOX 

(29).

 (

Refer to 

VIEW “A”).

 

 Hold

    the CONTROL BOX 

(29)

 so that it covers the wall opening

    and mark the four mounting hole locations as shown. 

Fig.

    7a.

4.

  It is recommended that the CONTROL BOX 

(29)

 be

     secured to a wall stud or cross brace within the wall using     
     the SCREWS 

(30)

 supplied. If the CONTROL BOX 

(29)

 is

     to be  installed on tile or plaster walls, the ANCHORS 

(31)

     and SCREWS 

(30)

 should be used.  

22

25

26

27

29 

31

30

28

24

15

23

Fig. 7

Fig. 7a

5b

VIE

W “

A”

VIEW “A”

32

35

33

34

24

29

Fig. 8

LAVATORY RIM OR
MOUNTING SURFACE

NOTE: If using Mixing Valve (optional) See Sheet 
#M968808 for installation instructions.

    CONNECT SPOUT HOSE TO
CONTROL BOX; Fig. 8

3

1. 

Connect G 1/2˝ end of SUPPLY HOSE 

(32)

 to the  

 

 ELBOW 

ASSEMBLY 

(24).

 Tighten with adjustable  

 

  wrench to make a water tight connection.

2. 

Connect G 3/8˝ end of SUPPLY HOSE 

(32)

 to nipple    

  on top of CONTROL BOX 

(29).

 Tighten with adjustable  

  wrench to make a water tight connection.

  3. IMPORTANT: INSERT FIBER WASHER (33) 
    INTO SUPPLY NUT (34) ON CONTROL BOX (29).

4. 

Connect FLEXIBLE SUPPLY 

(35)

 to bottom SUPPLY 

 NUT 

(34).

 Connect other end directly to wall supply.  

  Connection is G 3/8" compression.

Note: 

FLEXIBLE SUPPLY 

(35)

 measures 20" from the 

bottom of the CONTROL BOX 

(29)

 base. If additional 

supply length is required, installer must purchase parts 
separately. If FLEXIBLE SUPPLY 

(35)

 is too long, loop to 

avoid kinking.

COLD WATER OR

TEMPERED

WALL SUPPLY

CONTROL BOX

FOR HARDWIRE

INSTALLATION

(supplied by others)

9" TO 12"

(229mm TO 305mm)

NOTE: Find plastic bag containing 4 M5X16 screws 
to be used for securing the CONTROL BOX COVER (1) 
when installation is complete.

Summary of Contents for SERIN T064.34 Series

Page 1: ...nstallation instructions M965614 prior to faucet installation NOTE TO INSTALLER Please give this manual to the customer after installation NOTE TO INSTALLER Please give this manual to the customer after installation To learn more about American Standard Selectronic Products visit our website at www americanstandard us com or e mail us at CRTTEAM lixilamericas com For Parts Service Warranty or othe...

Page 2: ...begin UNPACKING 1 Remove the fitting and loose items from the carton The illustration below shows the fitting and all loose items after they have been removed from the carton Some items may be packaged partially assembled to other items 605XTMV1070 R350 MOUNTING KIT Must have R350 Mounting Kit installed prior to Wall Mount faucet installation PRODUCT No s 2 4 1 7 5 6 Mixing Valve B a s e P r o d u...

Page 3: ...DER 4b from falling back through the holes in the wall Remove the two EXTENSION CABLE ENDS 5b from the CABLE HOLDER 4b M965613 REV 1 9 12 17 Fig 1 2 3 8 COMP ELECTRICAL BOX supplied by others Roughing in Dimensions GENERAL DESCRIPTION Electronic faucet with proximity operation Vandal resistant solid brass construction single post mounting Operates on DC battery power pack or AC permanent power plu...

Page 4: ...ressing until secure connection is achieved INSTALL SPOUT ASSEMBLY Fig 3 1b 1 Connect the FAUCET SENSOR CONNECTORS 16 to the EXTENSION CABLES 5a and secure the connections by installing into CONNECTOR HOUSINGS 17 as shown Rotate the END CAPS 18 to secure the connection within the CONNECTOR HOUSINGS 17 2 Pull the bottom end of EXTENSION CABLES 5b so that the CONNECTOR HOUSINGS 17 are inside the wal...

Page 5: ...1 Once MOUNTING FLANGE 8 is installed move the SPOUT 12 in or out to determine desired spout length from finished wall Note The Min is 150mm 5 7 8 and the Max is 225mm 8 7 8 from the finished wall to center of the spout end 2 Tighten COMPRESSION RING 13 to MOUNTING FLANGE 8 by tightening the three COMPRESSION RING SCREWS 20 with HEX WRENCH 21 supplied This will fix SPOUT 12 length from finished wa...

Page 6: ...A 32 35 33 34 24 29 Fig 8 LAVATORY RIM OR MOUNTING SURFACE NOTE If using Mixing Valve optional See Sheet M968808 for installation instructions CONNECT SPOUT HOSE TO CONTROL BOX Fig 8 3 1 Connect G 1 2 end of SUPPLY HOSE 32 to the ELBOW ASSEMBLY 24 Tighten with adjustable wrench to make a water tight connection 2 Connect G 3 8 end of SUPPLY HOSE 32 to nipple on top of CONTROL BOX 29 Tighten with ad...

Page 7: ... Standard or PWRX Battery to EXTENSION CABLE 8 as shown Fig 1c Place Standard Battery or PWRX into Housing Fig 1d 6 Replace CONTROL BOX COVER 1 Tighten cover screws firmly PWRX STANDARD BATTERY Fig 1 A ELECTRICAL INSTALLATION Fig 1a Fig 1b Fig 1 Fig 1c 5 5 Fig 1d 3 2 1 6 7 INSTALL BATTERY STANDARD BATTERY STANDARD BATTERY PWRX CR P2 7a 7a 8 4 PWRX CAUTION Use only American Standard supplied transf...

Page 8: ... Fig 2a 5a Mount CONTROL BOX to wall Replace CONTROL BOX COVER 1 Tighten cover screws firmly 6a Plug AC POWER SUPPLY into wall outlet 2b Insert one end of the 10 EXTENSION 10a through POWER SUPPLY GROMMET 9 Fig 2b 3b Insert 10 EXTENSION 10a through side GROMMET 6 as shown Fig 2b 4b Connect one of the 27 EXTENSION CABLES 2 to SOLENOID CABLE 7 and the other to the 10 EXTENSION CABLE 10a Install CONN...

Page 9: ...the same end of the Y ADAPTER 13 Fig 4 and Fig 4a 5 Feed the other end of the 10 ft EXTENSION 11b through the two GRAY GROMMETS 4a and 4b and connect to the single terminal end of the next unit s Y ADAPTER 13 Place Y ADAPTER 13 into CONTROL BOX 2 as shown in Fig 4 and Fig 4a 6 Repeat Steps above for each additional Unit for a Max of 15 Units on one AC POWER SUPPLY 7 Replace CONTROL BOX COVERS Tigh...

Page 10: ...Install the FILTER ASSEMBLY 6 back in its place and tighten with a 7 16 socket Caution Do not over tighten 6 Open SUPPLY STOP 13 with 4mm Hex wrench 7 Replace CONTROL BOX COVER Tighten cover screws firmly HOWTO CLEAN FILTER ASSEMBLY Fig 3 C CAUTION Before opening CONTROL BOX disconnect AC power supply START UP MAINTENANCE When the Sensor detects a user the water immediately starts to flow Water fl...

Page 11: ... doesn t the water flow out of faucet when I m within the sensor detection zone A Battery may need replacement Check If sensor continuously blinks 2 times interrupted by pause replace battery or call 855 752 9259 Q What is the normal operating pressure range A Faucet will operate with supply pressures ranging from 20 80 psi Fig 5 1 Remove SUPPLY HOSE 10 from SPOUT ELBOW ASSEMBLY 11 Pull out FLOW R...

Page 12: ...S NO FULLY OPEN INTERNAL EXTERNAL SUPPLY STOPS BY TURNING COUNTER CLOCKWISE LOW FLOW COULD BE CAUSED BY DEBRIS IN THE FILTER ASSEMBLY FLOW REGULATOR OR AERATOR SPRAY REMOVE CLEAN AND INSERT BACK TO ORIGINAL POSITION ARE INTERNAL EXTERNAL SUPPLY STOPS FULLY OPEN REPLACE SOLENOID WATER IS CONTINUOUSLY RUNNING LOW FLOW ISSUES HOT LINE FOR HELP For toll free information and answers to your questions c...

Reviews: