8
1.
Remove the FAUCET SPOUT
(1)
by unthreading the
LEVER SCREW
(2)
and pulling off the LEVER
HANDLE
(3)
. Unthread the FAUCET SPOUT
SCREW
(4)
at the back of the FAUCET. Pull FAUCET
SPOUT
(1)
up and off. See
Fig. 2
in this section.
2.
Disconnect SENSOR CABLE
(1)
from SOLENOID
CABLE
(2)
.
Fig. 8.
3.
Unthread SOLENOID VALVE
(2)
from VALVE BODY
(
3)
.
Fig. 9.
4.
Remove FILTER SCREEN
(4)
from base of SOLENOID
VALVE
(2)
. Clean and replace.
Fig. 9.
5.
Thread SOLENOID VALVE
(2)
into VALVE BODY
(3)
and hand tighten. Reconnect SENSOR and SOLENOID
CABLES
(1). Fig. 8.
6.
Replace FAUCET SPOUT
(1)
and LEVER HANDLE
(3)
. Install LEVER HANDLE SCREW
(2)
, FAUCET
SPOUT SCREW
(4)
and tighten. See
Fig. 2
in this section.
CLEAN FILTER SCREEN ON
SOLENOID VALVE; Fig. 8 & 9
D
1.
Remove the FAUCET SPOUT
(1)
by unthreading the
LEVER SCREW
(2)
and pulling off the LEVER
HANDLE
(3)
. Unthread the FAUCET SPOUT
SCREW
(4)
at the back of the FAUCET. Pull FAUCET
SPOUT
(1)
up and off. See
Fig. 2
in this section.
2.
Pull out LIMITER STOP
(1)
from the VALVE STEM
(2)
. Unthread COLLAR NUT
(3)
from VALVE BODY
(4)
.
Fig. 10.
3.
Pull DIVERTER CARTRIDGE
(5)
out and replace
with new DIVERTER CARTRIDGE
(5)
.
NOTE: Make sure the two ALIGMENT PINS
(6)
in the
base of the DIVERTER CARTRIDGE
(5)
are facing
upward.
Fig. 11.
4.
Replace FAUCET SPOUT
(1)
and LEVER HANDLE
(3)
. Install LEVER HANDLE SCREW
(2)
, FAUCET
SPOUT SCREW
(4)
and tighten. See
Fig. 2
in this section.
REPLACE DIVERTER CARTRIDGE;
Fig. 10 & 11
E
Fig. 9
4
2
3
4
2
1
Fig. 10
Fig. 12
9
8
Fig. 8
6
5
Fig. 11
M965654 Rev. 2.2 (12/17)