background image

8

1. 

Remove the FAUCET SPOUT 

(1)

 by unthreading the 

    LEVER SCREW 

(2)

 and pulling off the LEVER 

    HANDLE 

(3)

. Unthread the FAUCET SPOUT 

    SCREW 

(4)

 at the back of the FAUCET. Pull FAUCET

    SPOUT 

(1)

 up and off. See 

Fig. 2 

in this section. 

2. 

Disconnect  SENSOR CABLE 

(1)

 from SOLENOID 

    CABLE 

(2)

Fig. 8.

3. 

Unthread SOLENOID VALVE 

(2)

 from VALVE BODY 

    (

3)

Fig. 9.

4.

 Remove FILTER SCREEN 

(4)

 from base of SOLENOID

     VALVE 

(2)

. Clean and replace. 

Fig. 9.

5.

 Thread SOLENOID VALVE 

(2)

 into VALVE BODY

 (3) 

    and hand tighten. Reconnect SENSOR and SOLENOID
    CABLES 

(1). Fig. 8. 

6. 

Replace FAUCET SPOUT 

(1)

 and LEVER HANDLE 

    

(3)

. Install LEVER HANDLE SCREW 

(2)

, FAUCET 

    SPOUT SCREW 

(4)

 and tighten. See 

Fig. 2 

in this section.       

    CLEAN FILTER SCREEN ON
SOLENOID VALVE; Fig. 8 & 9

D

1. 

Remove the FAUCET SPOUT 

(1)

 by unthreading the 

    LEVER SCREW 

(2)

 and pulling off the LEVER 

    HANDLE 

(3)

. Unthread the FAUCET SPOUT 

    SCREW 

(4)

 at the back of the FAUCET. Pull FAUCET 

    SPOUT 

(1)

 up and off. See 

Fig. 2 

in this section.    

2. 

Pull out LIMITER STOP 

(1)

 from the VALVE STEM 

    

(2)

. Unthread COLLAR NUT 

(3)

 from VALVE BODY 

(4)

.

    

Fig. 10.

3. 

Pull DIVERTER CARTRIDGE 

(5)

 out and replace 

    with new DIVERTER CARTRIDGE 

(5)

.

    NOTE: Make sure the two ALIGMENT PINS 

(6)

 in the

    base of the DIVERTER CARTRIDGE 

(5)

 are facing

    upward. 

Fig. 11.

  

4. 

Replace FAUCET SPOUT 

(1)

 and LEVER HANDLE 

    

(3)

. Install LEVER HANDLE SCREW 

(2)

, FAUCET 

    SPOUT SCREW 

(4)

 and tighten. See 

Fig. 2 

in this  section.         

     REPLACE  DIVERTER CARTRIDGE;
Fig. 10 & 11

E

Fig. 9

4

2

3

4

2

1

Fig. 10

Fig. 12

9

8

Fig. 8

6

5

Fig. 11

M965654 Rev. 2.2 (12/17)

Summary of Contents for SELECTRONIC 705X.105

Page 1: ...americas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC Integrated Faucet with Above...

Page 2: ...below deck User adjustable above deck mixing uses ceramic disc valve for dependability long life Mixing handle can be removed for one time temperature setting during installation Installation Instruct...

Page 3: ...through hole in ESCUTCHEON with PUTTY PLATE 2 and mounting surface Make sure PIN 6 is in back 3 Assemble RUBBER WASHER 7 BRASS WASHER 8 and THREADED LOCKNUT 9 onto SHANK 4 from underside of sink or mo...

Page 4: ...enter lines as shown 4 Place the BRACKET 5 on the horizontal center line and mark the location of the mounting holes to be drilled 5 Using 1 4 diameter drill bit drill two mounting holes aproximately...

Page 5: ...structions refer to section B page 3 For subsequent Units refer to instructions below C 1 Connect one end of the 10 EXTENSION 1 to the available terminal of the previous unit s Y ADAPTER 2 and the oth...

Page 6: ...LINE FILTER 3 on each wall supply outlet Be sure that INLINE FILTER 3 is inserted in the correct direction See Illustration 3 Connect HOT FLEXIBLE SUPPLY marked with red stripe 1 to INLINE FILTER 3 on...

Page 7: ...tion and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection d...

Page 8: ...a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET SPOUT 3 Remove O RING 5 Remove SENSOR 2a from CARRIER 4 and replace with new SENSOR 2a Replace O RING 5 Install SENSOR ASSEMBLY 2 into FAUCET SP...

Page 9: ...hten See Fig 2 in this section CLEAN FILTER SCREEN ON SOLENOIDVALVE Fig 8 9 D 1 Remove the FAUCET SPOUT 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET SPOUT...

Page 10: ...not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has the flow rate of the faucet reduced significantly A The filter assembly flow regulator or areator...

Page 11: ...FUNCTION 1 1 2 2 YES YES NO NO YES NO OPEN EXTERNAL SUPPLY STOPS CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLA...

Reviews: