background image

Fig. 12b

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

M968699 Rev. 1.3

9

6

1. 

Remove COVER 

(1)

 from SUPPLY STOP 

(2) 

if 

installed. 

Fig. 10.

 

2.

 Turn water supply off. 

Fig. 10.

3.

 Loosen SPUD COUPLING NUT 

(3)

. Unthread 

COUPLING NUT 

(4)

 and VACUUM BREAKER 

COUPLING NUT 

(5)

. Remove FLUSH VALVE 

(6)

.

Fig. 10.

4.

 Clean all threaded connections before installing the 

new flush valve. 

Fig. 10a.

5. 

Refer to 

Sections 5,6 and 7

 to complete the retrofit 

installation. 

Fig. 10b.

Note: In most Retrofits the wall escutcheon, supply stop, 
cover tube and vacuum breaker do not have to be replaced. 
If these items do need replacement they must be purchased 
separately or order the complete flush valve assembly from 
American Standard.

    HOW TO RETROFIT OUR VALVE;
Fig. 10

8

(Replaces Industry Standard Manual and
Electronic Valves)

CLEAN
CONNECTIONS

2

Fig. 10

Fig. 10a

Fig. 10b

1

4
5

3

6

  1. 

 Loosen SET SCREW 

(1)

 with 2.5mm Hex Wrench 

(2)

 in back of top half of FLUSH VALVE CAP 

(3)

Fig. 

12a.

2.

 Rotate CAP 

(3)

 to the right and pull off. 

Fig. 12b.

3. 

Turn CAP

 (3) 

over and remove the two SCREWS 

(4)

. Remove the BATTERY COVER 

(5)

 to expose the  

battery 

(6)

. Remove old BATTERY 

(6)

Fig. 12c.

4.

 Install the new BATTERY 

(7)

 making sure the + & - 

are facing up towards the open end of the cover.

Fig. 12d.

5. 

Replace the BATTERY COVER 

(5)

, reverse the 

above steps to assembly flush valve.   

    HOW TO CHANGE THE BATTERY;
Fig. 12

1

5

7

4

6

6

Fig. 12a

Fig. 12c

Fig. 12d

Fig. 12

OLD

BATTERY

OUT

NEW

BATTERY

IN

2

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

3

Summary of Contents for SELECTRONIC 6065.121

Page 1: ... can be adjusted manually or with optional remote control Sensor Features Low Battery Indicator M968699 Rev 1 3 6065 161 6065 121 6065 565 MODEL NUMBERS 6065 162 6065 122 6065 525 CLOG RESISTANT Self cleaning piston valve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with...

Page 2: ...s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n s In Toronto Area only 1 905 3061093 Certified to comply with ASME A112 19 2M 2008 AS America Inc NOTE TO INSTALLER Please give this manual to the customer after installation SELECTRONIC PROXIMITY TOILET FLUSH VALVE 1 28 1 6 GPF Exposed Flushometer for 1 1 2 Top Spud Bowls CLOG RESISTANT Self cleaning piston valve prevents clogging ...

Page 3: ...ponents should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accordance with applicable codes and regulations Water supply lines must be sized to provide an adequate volume of water for each fixture 2 Fig 1 Roughing in Dimensions GENERAL DESCRIPTION Right or Left Hand Installation 10 Exposed Flushometer for 1 1 ...

Page 4: ...weat Solder Adapter Supplied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any rough edges off the end of the supply pipe 3 Clean the end of the supply pipe Push the threaded Adapter on until it is seated against the internal stop Sw...

Page 5: ... Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2 5mm Hex Wrench 4 in back of top half of FLUSH VALVE 2 Fig 7a 2 Rotate TOP 2 to the right and pull off Fig 7b 3 Rotate bottom half of FLUSH VALVE 3 180 Fig 7b 4 Replace TOP 2 and rotate until key enga...

Page 6: ...ximately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER 2 and tighten to ensure vandal resistance ADJUST SUPPLY STOP Fig 9 7 3 Fig 8a 3 2 5 1 1 As shown in Fig 8a insert the side INLET FLANGE 1 on the FLUSH VALVE 2 into the SUPPLY STOP 3 Lubricate the IN...

Page 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b 1 4 5 3 6 1 Loosen SET SCREW 1 with 2 5mm Hex Wrench 2 in back of top half of FLUSH VALVE CAP 3 Fig 12a 2 Rotate CAP 3 to the right and pull off Fig 12b 3 Turn CAP 3 over and remove the two SCREWS 4 R...

Page 8: ...nt of the sensor Fig 14a 6 When the LED 6 stops blinking and stays ON move your hand to the desired position from sensor detection zone 1 1 2 to 31 38 to 787mm and hold in place until the LED 6 begins to blink again Fig 14b Note Detection Zone is 1 1 2 to 31 38 to 787mm from sensor 7 Once the SENSOR CONTROL LED 6 begins to blink again remove your hand from the detection zone When the flashing stop...

Page 9: ... FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VALVE OBSTRUCTED CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH NO UNIT IS CONTINUOUSLY FLUSHING PUSH MANUAL FLUSH BUTTON DOES IT RETURN LOOK FOR REPEATED DOUBLE FLASH ON SENSOR NO NO YES NO 1 COVER SEN...

Page 10: ...BLY W MTG KIT FOR FLUSH VALVE WITH1 28 gpf A923654 0070A BATTERY 6VCR P2 M962666 0020A MANUAL VALVE M962664 0070A SOLENOID ASSEMBLY M962663 0070A PISTON ASSEMBLY A906680 0070A BONNET NUT A955066 0020A ADJUSTABLE TAILPIECE A955057 0020A INLET PIPE ASSEMBLY A955054 0020A VACUUM BREAKER ASSEMBLY 220mm A955068 0020A VACUUM BREAKER ASSEMBLY 610mm M962665 0021600A COVER ASSEMBLY FOR FLUSH VALVE WITH1 6 ...