NOTE TO INSTALLER: Please give this manual to the customer after installation.

SELECTRONIC™

PROXIMITY TOILET FLUSH VALVE

1.28 & 1.6 GPF

Exposed Flushometer
for 1-1/2

"

 Top Spud Bowls

CLOG RESISTANT

• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL

• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.

M968699 Rev.1.3

6065.161
6065.121 
6065.565

MODEL NUMBERS

6065.162
6065.122
6065.525

CLOG RESISTANT

• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL

• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.

To learn more about American Standard Faucets visit our website at: 

www.americanstandard-us.com

or U.S. customer's e-mail us at: 

[email protected]

For Parts, Service, Warranty or other Assistance, 

please call

 

1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-3061093)

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Summary of Contents for SELECTRONIC 6065.121

Page 1: ... can be adjusted manually or with optional remote control Sensor Features Low Battery Indicator M968699 Rev 1 3 6065 161 6065 121 6065 565 MODEL NUMBERS 6065 162 6065 122 6065 525 CLOG RESISTANT Self cleaning piston valve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with...

Page 2: ...s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n s In Toronto Area only 1 905 3061093 Certified to comply with ASME A112 19 2M 2008 AS America Inc NOTE TO INSTALLER Please give this manual to the customer after installation SELECTRONIC PROXIMITY TOILET FLUSH VALVE 1 28 1 6 GPF Exposed Flushometer for 1 1 2 Top Spud Bowls CLOG RESISTANT Self cleaning piston valve prevents clogging ...

Page 3: ...ponents should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accordance with applicable codes and regulations Water supply lines must be sized to provide an adequate volume of water for each fixture 2 Fig 1 Roughing in Dimensions GENERAL DESCRIPTION Right or Left Hand Installation 10 Exposed Flushometer for 1 1 ...

Page 4: ...weat Solder Adapter Supplied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any rough edges off the end of the supply pipe 3 Clean the end of the supply pipe Push the threaded Adapter on until it is seated against the internal stop Sw...

Page 5: ... Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2 5mm Hex Wrench 4 in back of top half of FLUSH VALVE 2 Fig 7a 2 Rotate TOP 2 to the right and pull off Fig 7b 3 Rotate bottom half of FLUSH VALVE 3 180 Fig 7b 4 Replace TOP 2 and rotate until key enga...

Page 6: ...ximately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER 2 and tighten to ensure vandal resistance ADJUST SUPPLY STOP Fig 9 7 3 Fig 8a 3 2 5 1 1 As shown in Fig 8a insert the side INLET FLANGE 1 on the FLUSH VALVE 2 into the SUPPLY STOP 3 Lubricate the IN...

Page 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b 1 4 5 3 6 1 Loosen SET SCREW 1 with 2 5mm Hex Wrench 2 in back of top half of FLUSH VALVE CAP 3 Fig 12a 2 Rotate CAP 3 to the right and pull off Fig 12b 3 Turn CAP 3 over and remove the two SCREWS 4 R...

Page 8: ...nt of the sensor Fig 14a 6 When the LED 6 stops blinking and stays ON move your hand to the desired position from sensor detection zone 1 1 2 to 31 38 to 787mm and hold in place until the LED 6 begins to blink again Fig 14b Note Detection Zone is 1 1 2 to 31 38 to 787mm from sensor 7 Once the SENSOR CONTROL LED 6 begins to blink again remove your hand from the detection zone When the flashing stop...

Page 9: ... FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VALVE OBSTRUCTED CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH NO UNIT IS CONTINUOUSLY FLUSHING PUSH MANUAL FLUSH BUTTON DOES IT RETURN LOOK FOR REPEATED DOUBLE FLASH ON SENSOR NO NO YES NO 1 COVER SEN...

Page 10: ...BLY W MTG KIT FOR FLUSH VALVE WITH1 28 gpf A923654 0070A BATTERY 6VCR P2 M962666 0020A MANUAL VALVE M962664 0070A SOLENOID ASSEMBLY M962663 0070A PISTON ASSEMBLY A906680 0070A BONNET NUT A955066 0020A ADJUSTABLE TAILPIECE A955057 0020A INLET PIPE ASSEMBLY A955054 0020A VACUUM BREAKER ASSEMBLY 220mm A955068 0020A VACUUM BREAKER ASSEMBLY 610mm M962665 0021600A COVER ASSEMBLY FOR FLUSH VALVE WITH1 6 ...