background image

7

5

TEST INSTALLED FAUCET

SPRAY OPERATION

With FAUCET on, press TOGGLE BUTTON 

(6)

 on

SPRAY 

(3) 

to switch from stream to spray. 

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

STREAM (AERATOR)

SPRAY

1

3

6

Move HANDLE 

(1)

 into "off" position.

With HANDLE 

(1)

 in "off" position, pull HAND SPRAY 

(2)

 from SPOUT 

(3). 

SPRAY HOSE 

(4)

 should pull

approximately 2 feet and direct open SPRAY END 

(5)

 into sink.

Operate handle up and down, in COLD and HOT positions,

to flush water lines thoroughly.

Check HAND SPRAY 

(2)

 operation:

SERVICE

6

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

1

2

4

If Faucet Drips Proceed As Follows:

     Turn VALVE in OFF position.

     If faucet drips, operate HANDLE several times  from OFF to ON position.  

     Do not apply excessive force.
     FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW 

     CONTROL DEVICE, unthread SPRAY AND HOSE ASSEMBLY and 

     rinse clean FLOW CONTROL DEVICE.

Remove INDEX BUTTON 

(1)

, loosen HANDLE SCREW 

(2)

and remove HANDLE 

(3)

.

Unthread ESCUTCHEON CAP 

(4)

. Unthread three MOUNTING

SCREWS 

(5)

.

Lift CARTRIDGE 

(6)

 off MANIFOLD 

(7)

 and remove CARTRIDGE

SEALS 

(8)

.

Place SEALS 

(8)

 into CARTRIDGE PORTS 

(6a)

.

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten

HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

Test fitting.

Clean MANIFOLD 

(7)

, CARTRIDGE 

(6)

 ports and SEALS 

(8)

.

Place CARTRIDGE 

(6)

 onto MANIFOLD 

(7)

 and tighten

MOUNTING SCREWS 

(5)

 alternately.

 

5

6

8

7

6a

5

3

4

2

FLOW CONTROL

DEVICE

SPRAY AND HOSE

ASSEMBLY

M 9 6 5 2 4 5   R E V.  1. 2

3

Summary of Contents for QUINCE 4433.150F15

Page 1: ...ructions Certified to comply with ANSI A112 18 1M 4433 150 QUINCE Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin M965245 REV 1 2 A Installation with ESCUTCHEON 1 Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE 1 Make certain th...

Page 2: ...IBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left supply Marked with a Red Stripe to Hot and right supply Marked with Blue Stripe to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten Faucet supplies are 21 long from faucet base Note If additional supply length is required installer must purchase additional pa...

Page 3: ...y cause reduced flow To clean first turn off water supply then 1 2 4 If Faucet Drips Proceed As Follows Turn VALVE in OFF position If faucet drips operate HANDLE several times from OFF to ON position Do not apply excessive force FLOW CONTROL DEVICE may accumulate dirt To remove the FLOW CONTROL DEVICE unthread SPRAY AND HOSE ASSEMBLY and rinse clean FLOW CONTROL DEVICE Remove INDEX BUTTON 1 loosen...

Page 4: ...oll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1200 P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c A S A m e r i c a I n c 2 0 1 2 HOT LINE FOR HELP M952244 YYY220A 2 2 G...

Reviews: