American Standard MAYBROOK 6581 Series Installation Instructions Manual Download Page 5

7301812-100FR

L e s   n o m s   d e s   p r o d u i t s   m e n t i o n n é s   d a n s   l e   p r é s e n t   d o c u m e n t   s o n t   d e s   m a r q u e s   d e   c o m m e r c e   d e   A S   A m e r i c a ,   I n c .
©   A S   A m e r i c a   I n c .   2 0 1 5

SÉRIES 6581

URINOIR MAYBROOK

®

INSTRUCTIONS D'INSTALLATION

OUTILS ET MATÉRIAUX RECOMMANDÉS

Lunettes de sécurité 

Ruban à mesurer 

Clé universelle 

Tournevis à lame 

Crayon 

Niveaux

Scellant pour filet 

Cliquet 1/4 po 

Équipement pour la découpe de trous

AVANT DE COMMENCER....

CONSER

VER POUR US

A

GE UL

TÉRIEUR

AVERTISSEMENT : CE PRODUIT EST FRAGILE. POUR ÉVITER LES BRIS ET DES BLESSURES, MANIPULER AVEC SOIN !

NOTES : 

• 

Les dessins peuvent ne pas correspondre exactement aux contours de l'appareil ou des composants.

•  Respecter tous les codes locaux de plomberie et du bâtiment.
•  Se reporter aux codes locaux et aux instructions du fabricant pour les exigences relatives à la valve de chasse.
•  Inspecter avec soin le nouvel urinoir afin de déceler tout dommage.
•  Les dimensions du robinet sont nominales et sont conformes aux seuils de tolérance établis d'après les 

normes ASME A112.19.2.

•  La préparation du site peut nécessiter des outils et de la quincaillerie supplémentaires.

Nous vous remercions d'avoir choisi American Standard - synonyme de qualité supérieure depuis plus de 100 ans. Pour 
être  sûr  que  ce  produit  soit  bien  installé,  veuillez  lire  attentivement  ces  instructions  avant  de  commencer.  (Certaines 
installations peuvent requérir une aide professionnelle.) Assurez-vous également que votre installation soit conforme aux 

codes locaux.

!

ÉTRIERS K2

PLANCHER

FINI

292mm

(11-1/2 po)

324mm

(12-3/4 po)

121mm

(4-3/4 po)

298mm

(11-3/4 po)

457mm

(18 po)

133mm

(5-1/4 po)

TROUS D'UN DIA. DE

10mm (3/8 po)

171mm

(6-3/4 po)

VIDANGE D'UN DIA. EXT. DE

38mm (1-1/2 po)

ABOUT D'UN DIA. EXT. 

DE 38mm (1-1/2 po)

32mm

(1-1/4 po)

DIA. SUGGÉRÉ

*

298mm

(11-3/4")

292mm

(11-1/2 po)

324mm

(12-3/4 po)

19mm 

(3/4 po) 

RACCORD

64mm

(2-1/2 po)

178mm

(7 po)

OPTIONNEL 

JUSQU'AU 

PLANCHER FINI

610mm 

(24 po) MAX

19mm (3/4 po) N.P.T. ou C.W.T. 

TUYAU À LA VALVE DE CHASS

*

 PIÉGER P - 

VENDU SÉPARÉMENT

Summary of Contents for MAYBROOK 6581 Series

Page 1: ...amage Fixture dimensions are nominal and conform to tolerances by ASME Standard A112 19 2 Site preparation may require additional tools and hardware Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also ...

Page 2: ...s b Connect the water supply and complete the waste pipe connections c Turn on the water supply d Flush and check the entire installation for leaks COMPLETE THE INSTALLATION 3 Wash with mild soapy water and rinse thoroughly Dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans as they may damage fittings CARE CLEANING Screw Washer In the United States American S...

Page 3: ...mingitorio para ver si tiene daños Las dimensiones del accesorio son nominales y cumplen con las tolerancias establecidas por la norma ASME A112 19 2 La preparación del sitio puede requerir herramientas y accesorios adicionales Gracias por elegir American Standard el parámetro de primera calidad por más de 100 años Para asegurarse de que el producto esté instalado correctamente por favor lea estas...

Page 4: ...s del fabricante b Conecte el suministro de agua y complete las conexiones del tubo de desagüe c Abra el suministro de agua d Descargue y revise toda la instalación para ver si tiene fugas COMPLETE LA INSTALACIÓN 3 Gancho de pared Acople de entrada Tuerca de acoplamiento y pieza posterior Gancho de pared instalado Acople de salida 38mm x 38mm 1 1 2 x 1 1 2 Lave con agua y jabón suave y enjuague bi...

Page 5: ...er avec soin le nouvel urinoir afin de déceler tout dommage Les dimensions du robinet sont nominales et sont conformes aux seuils de tolérance établis d après les normes ASME A112 19 2 La préparation du site peut nécessiter des outils et de la quincaillerie supplémentaires Nous vous remercions d avoir choisi American Standard synonyme de qualité supérieure depuis plus de 100 ans Pour être sûr que ...

Page 6: ...ccorder l alimentation en eau et finaliser le raccordement du tuyau de drain c Ouvrir l alimentation en eau d Rincer et vérifier l ensemble de l installation afin de déceler toute fuite TERMINER L INSTALLATION 3 Fixation murale Support Mur Ergot d entrée Écrou d assemblage et about Fixation murale installée Ergot de sortie 38mm x 38mm 1 1 2 po x 1 1 2 po Laver avec de l eau savonneuse et rincer à ...