American Standard MAYBROOK 6581 Series Installation Instructions Manual Download Page 2

7301812-100

- 2 -

1

a.  Turn the water supply OFF.
b.  Install or relocate the supply tubing and waste pipe as necessary  
  to conform to the roughing in dimensions.
c.  Install the shut off valve.
d.  Install adequate support framing for the wall hanger as needed.

PREPARATION

a.  Install the wall hanger according to the roughing in illustration.
b.  Apply thread sealant tape to the pipe threads and install the coupling nut and tailpiece to the waste “U” pipe.
c.  Carefully position the urinal on the wall hanger.
d.  Secure the urinal to the wall using the screws and washers provided.

INSTALL THE URINAL

2

CAUTION: RISK OF PERSONAL INJURY OR PRODUCT DAMAGE.  HANDLE WITH CARE.  
VITREOUS CHINA CAN BREAK OR CHIP IF THE PRODUCT IS HANDLED CARELESSLY.

!

CAUTION: RISK OF PRODUCT DAMAGE.  DO NOT OVERTIGHTEN THE BOLTS.

!

a.  Install the flush valve according to the manufacturer’s instructions.
b.  Connect the water supply and complete the waste pipe connections.
c.  Turn on the water supply.
d.  Flush and check the entire installation for leaks.

COMPLETE THE INSTALLATION

3

Wash with mild soapy water and rinse thoroughly.  Dry with a soft cloth.  Avoid detergents, disinfectants or cleaning 
products in aerosol cans as they may damage fittings.

CARE & CLEANING

Screw

Washer

In the United States:

American Standard Brands

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of Customer Care

For residents of the United States, warranty 

information may also be obtained by calling 

the following toll free number: (800) 442-1902

www.americanstandard.com

In Canada:

AS Canada, ULC

5900 Avebury Rd.  

Mississauga, Ontario 

Canada L5R 3M3

Toll Free:  (800) 387-0369

www.americanstandard.ca

In Mexico:

American Standard B&K Mexico

S. de R.L. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

Toll Free: 01-800-839-1200

www.americanstandard.com.mx

Wall Hanger

Support

Wall

Inlet Spud

Coupling Nut

and Tailpiece

Installed Wall Hanger

Outlet Spud

1-1/2" x 1-1/2"

Summary of Contents for MAYBROOK 6581 Series

Page 1: ...amage Fixture dimensions are nominal and conform to tolerances by ASME Standard A112 19 2 Site preparation may require additional tools and hardware Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also ...

Page 2: ...s b Connect the water supply and complete the waste pipe connections c Turn on the water supply d Flush and check the entire installation for leaks COMPLETE THE INSTALLATION 3 Wash with mild soapy water and rinse thoroughly Dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans as they may damage fittings CARE CLEANING Screw Washer In the United States American S...

Page 3: ...mingitorio para ver si tiene daños Las dimensiones del accesorio son nominales y cumplen con las tolerancias establecidas por la norma ASME A112 19 2 La preparación del sitio puede requerir herramientas y accesorios adicionales Gracias por elegir American Standard el parámetro de primera calidad por más de 100 años Para asegurarse de que el producto esté instalado correctamente por favor lea estas...

Page 4: ...s del fabricante b Conecte el suministro de agua y complete las conexiones del tubo de desagüe c Abra el suministro de agua d Descargue y revise toda la instalación para ver si tiene fugas COMPLETE LA INSTALACIÓN 3 Gancho de pared Acople de entrada Tuerca de acoplamiento y pieza posterior Gancho de pared instalado Acople de salida 38mm x 38mm 1 1 2 x 1 1 2 Lave con agua y jabón suave y enjuague bi...

Page 5: ...er avec soin le nouvel urinoir afin de déceler tout dommage Les dimensions du robinet sont nominales et sont conformes aux seuils de tolérance établis d après les normes ASME A112 19 2 La préparation du site peut nécessiter des outils et de la quincaillerie supplémentaires Nous vous remercions d avoir choisi American Standard synonyme de qualité supérieure depuis plus de 100 ans Pour être sûr que ...

Page 6: ...ccorder l alimentation en eau et finaliser le raccordement du tuyau de drain c Ouvrir l alimentation en eau d Rincer et vérifier l ensemble de l installation afin de déceler toute fuite TERMINER L INSTALLATION 3 Fixation murale Support Mur Ergot d entrée Écrou d assemblage et about Fixation murale installée Ergot de sortie 38mm x 38mm 1 1 2 po x 1 1 2 po Laver avec de l eau savonneuse et rincer à ...

Reviews: