Whole House Air Cleaner Upgrade Kit

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit.

Please return to service information pack upon completion of work.

Installation
Operation
Maintenance

Upflow Furnace
Models

*FD145ALUPGRDA
*FD175ALUPGRDA
*FD210ALUPGRDA
*FD245ALUPGRDA

18-HE56D1-3

WARNING

!

This information is for use by individuals having adequate
backgrounds of electrical and mechanical experience. Any
attempt to repair a central air conditioning product may
result in personal injury and/or property damage. The
manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any
liability in connection with its use.

Contents

Installation

2

Location

2

TFE Models Only

3

Enclosure Upgrade

4-7

Electrical Connections

8

Wiring Diagrams

8

Air Cleaner Operation

9

Set-Up Mode

9

PRE-FILTER Setting

9

Collection Cell Setting

10

Power Level Setting

10

Maintenance

10

Cleaning

10

Fuse Replacement

11

Troubleshooting

12

Outline drawings

13-15

Downflow Furnace
Models

*FD14DALUPGRDA
*FD17DALUPGRDA
*FD21DALUPGRDA
*FD24DALUPGRDA

Air Handler
Models

*FD215ALUPGRDA
*FD235ALUPGRDA
*FD260ALUPGRDA
*May be "A" or "T"

WARNING

!

RISK OF ELECTRIC SHOCK: These servicing
instructions are for use by qualified personnel only. To
reduce the risk of electric shock, do not perform any
servicing other than that contained in these operating
instructions unless you are qualified to do so.

Summary of Contents for FD145ALUPGRDA

Page 1: ...be responsible for the interpretation of this information nor can it assume any liability in connection with its use Contents Installation 2 Location 2 TFE Models Only 3 Enclosure Upgrade 4 7 Electri...

Page 2: ...f the system Unpack the Air Cleaner and check to make sure all compo nents are included They consist of 1 PRE FILTER traps large particles such as hair and lint before they can enter the COLLECTION CE...

Page 3: ...ized connector from the air handler control box See Figure 4 to the right 3 Reconnect the female polarized connector on the heater and the male polarized connector from the air handler control box 4 D...

Page 4: ...enclosure and discard DUCT ALIGNMENT PIN FURNACE AIR HANDLER TEMPLATE AIRFLOW Installation template must be fully seated against front edge and also against the 1 pre filter rail for proper installat...

Page 5: ...e with two screws it may be desirable to add an optional third screw on the rail for extra support A third hole is provided for this purpose as well as a screw Use the existing hole located in the cen...

Page 6: ...E FILTER and COLLECTION CELLS 13 Each COLLECTION CELL must be oriented with the handles toward the front 14 The door can be installed in either direction Deter mine which direction will best allow acc...

Page 7: ...R INSTALLATION Place circular foam disc pads over screw tips protruding from case Repeat on other side Third screw and foam sticker Optional 15 After installing the middle filter mount rails into the...

Page 8: ...andard Furnace applications and 75 VA required for Trane American Standard Air Handler applications If the indoor air handler already has a properly sized transformer no replacement is required WARNIN...

Page 9: ...es before the air cleaner starts to operate each time the power to the air cleaner is turned off on This can be bypassed by going into and then out of the Set Up mode SET UP MODE A combination of RED...

Page 10: ...Factory Setting MAINTENANCE For maximum efficiency the COLLECTION CELLS and PRE FILTER should be inspected and cleaned on a regular basis The FIELD CHARGER should only be removed and cleaned annually...

Page 11: ...e unit detects 10 consecutive run cycles where an arc occurs during the cycle it will go into a lock out period for one hour This is indicated by three FLASHING YELLOW LED s The PRE FILTER and COLLECT...

Page 12: ...here is no High Voltage being provided to the FIELD CHARGER or the COLLECTION CELLS Inspect the FIELD CHARGER assembly and COLLECTION CELLS for any foreign material that may be lodged in them Clean as...

Page 13: ...D145ALUPGRDA 14 5 12 38 FD175ALFR000A FD175ALUPGRDA 17 5 15 38 FD210ALFR000A FD210ALUPGRDA 21 0 18 88 FD245ALFR000A FD245ALUPGRDA 24 5 22 38 May be A or T OUTLINE DRAWING FOR UPFLOW FURNACES 2 8 27 DE...

Page 14: ...D14DALUPGRDA 14 5 12 38 FD17DALFR000A FD17DALUPGRDA 17 5 15 38 FD21DALFR000A FD21DALUPGRDA 21 0 18 88 FD24DALFR000A FD24DALUPGRDA 24 5 22 38 May be A or T OUTLINE DRAWING FOR DOWNFLOW FURNACES 2 8 21...

Page 15: ...NDLERS 2 8 AIR HANDLER MODEL NUMBERS ifD Air Cleaner A B FD215ALAH000A FD215ALUPGRDA 21 5 19 38 FD235ALAH000A FD235ALUPGRDA 23 5 21 38 FD260ALAH000A FD260ALUPGRDA 26 0 23 88 May be A or T 21 0 18 88 2...

Page 16: ...14 0 19 0 24 0 30 FD210ALFR000A FD210ALUPGRDA 0 02 0 04 0 07 0 10 0 13 0 17 0 21 0 26 0 31 FD245ALFR000A FD245ALUPGRDA 0 01 0 03 0 05 0 07 0 10 0 13 0 16 0 19 0 23 FD14DALFR000A FD14DALUPGRDA 0 07 0 1...

Reviews: