background image

FB104

FB105

FB109                        

0.35 - 1.8 L/min

0.35 - 1.8 L/min

Status

Cause

Solution

Water is too low during 

WASH/BIDET

1. Low water pressure of the unit

2. Low water pressure of water supply

During WASH/BIDET, turn the lever fast to biggest volume

When water supply pressure is lower than 0.7kgf/cm  , contact 

local department for water pressure question

No water comes out 

during WASH/BIDET

1. Water shut-off valve is turned off

Turn on the water shut-off valve

2. Filter net of T-shaped connector is stuck Clean the filter net of T-shaped connector 

3.Filter net of water inlet hose is stuck

Clean the filter net of water inlet hose

4. Nozzle head is stuck

Take off and clean the nozzle head.

5. External water pressure is low

Increase external water pressure.

Water dropping from bowl

 when using the unit

The maximum water pressure of the unit is 0.8MPa . If water supply

 pressure is higher than that, please contact local department for water

 pressure question.

External water pressure is too big

If any failure still occurs after above trouble-shooting, please contact local service.

Classification

Description

FB104

FB105

FB106

FB107

FB108

FB109

Model No.

Check valve, vacuum breaker

Water Supply

Direct from water pipes

Water Pressure Range

Dimensions

Weight

Caution

Do not disassemble, repair or remodel the unit.

Self Diagnosis and Trouble shooting

WASH water flow 

BIDET water flow 

Backflow Prevention

Specifications

    Thank you for choosing the product! If failure or damage occurs, please 

check the product based on the trouble shooting guide in this manual first. 

If the failure/damage could not be fixed, please contact the retailer or local 

service center with proof of purchase.

FB106

FB107                                       

FB108                                                    

FB104:   2.23    KG

FB105:   2.22    KG

FB106:   2.09    KG

FB107:   2.08    KG

FB108:   2.00    KG

FB109:   2.16    KG

370X500X62mm

370X480X62mm

370X500X60mm

Static pressure:0.07- 0.8 MPa,Dynamic pressure:above 0.03MPa

6

9

Summary of Contents for FB104

Page 1: ...FB104 FB105 FB106 FB107 FB108 FB109 FB104 FB105 FB106 FB107 FB108 FB109 6 5 Product Maintenance 9 9 9 4 3 2 1 ...

Page 2: ...t 1 Main body 2 Installation template Connecting bolts 2 Sliding plates 2 5 T shaped connector 6 Water hose 7 Installation and User Manual Installation and User Manual 3 Fixing Components Expansive nuts 2 Rubber gasket 2 Adaptable panel Filter Nut 2 Note There are two methods for installation The way of employing expansive nuts is recommended Another way is using butterfly nuts Please choose one f...

Page 3: ...nstallation template Installation template Second installation method 1 Refer to first installation method step 1 and 3 Dismantle the old seat and lid Put the installation template on the ceramic 2 Refer to fist installation method step 4 Take the adaptable panel to the holes of the ceramic Adjust position of the connecting bolts with adjusting pieces Screw in the nuts form underside of the cerami...

Page 4: ...be then connect the main body and T shaped connector with water hose Washer Filter Connecting water hose Prohibition 1 Do not lift the product with the seat cover and seat open 2 Cannot use with the hot water which temperature is higher than 40 C This may cause a mechanical trouble 4 Open the water valve to check if there is any leakage 1 3 2 Note Please remove the regulator cover and regulate o r...

Page 5: ...move the old lever along the axis direction As per figure B insert the new lever rib into the corresponding control valve slot The installation is completed with a click sound As per figure A Pull out the tube and do not release then remove the old nozzle along the axis direction As per figure B insert the new nozzle into the tube along the corresponding slot The nozzle replacement is completed If...

Page 6: ...MPa If water supply pressure is higher than that please contact local department for water pressure question External water pressure is too big If any failure still occurs after above trouble shooting please contact local service Classification Description FB104 FB105 FB106 FB107 FB108 FB109 Model No Check valve vacuum breaker Water Supply Direct from water pipes Water Pressure Range Dimensions We...

Page 7: ......