CARTRIDGE INLETS

MANIFOLD

1

2

3

4

M968882 Rev. 1.7 (11/17)

10

•  With HANDLE 

(1)

 in OFF position, turn on WATER 

SUPPLIES 

(2)

 and check all connections for leaks.

•  Ensure that AERATOR 

(3)

 is tightened completely.

•  Operate HANDLE 

(1)

 to allow water flow.

ADJUST HOT LIMIT STOP

TEST INSTALLED FITTING

9

3

2

5

2

“P” TRAP

WASTE

OUTLET

4

1

•  Operate POP-UP KNOB

 (4)

 and fill lavatory with water. 

Check that DRAIN STOPPER 

(5)

 makes a good seal 

and retains water in Sink. If DRAIN STOPPER 

(5)

 

does not seal properly, please refer to Troubleshooting 
section in these instructions.

•  Release POP-UP KNOB 

(4)

 down and check all drain 

connections and 

“P” trap

 for leaks.        Tighten 

if necessary.

CHECK DRAIN CONNECTIONS

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP 
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust 
the setting on the HOT LIMIT SAFETY STOP. 

•  Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP 

(1)

. Follow Step “A” or “B” to  

adjust min./max. discharge temperature. “1” being the hottest to “8” the coldest temperature setting. Factory set at “1”.

- 4 -

11

SERVICE

PRY RED RING UPWARD

AND ROTATE

COUNTER-CLOCKWISE

"A"

ADJUSTMENT WHEN WATER IS TOO HOT

PRY RED RING UPWARD

AND ROTATE CLOCKWISE 

"B"

ADJUSTMENT WHEN

WATER IS TOO COLD

"RED RING"- HOT LIMIT SAFETY STOP

"B"

"A"

TEMPERATURE
SETTING NUMBERS

If Faucet Drips Proceed As Follows

•  Turn VALVE in OFF position.
•  If faucet drips, operate handle  several times from “off” to “on”.  

Do not apply excessive force.

•  Clogged CARTRIDGE INLETS may cause reduced flow in “full on” hot 

or cold. To clean inlets, first turn off water supply, then:

•  Remove HANDLE 

(1)

, CAP 

(2)

 and CARTRIDGE 

(3)

.

•  Clean CARTRIDGE INLETS and MANIFOLD.
•  Reassemble CARTRIDGE 

(3)

, alternately tightening SCREWS 

(4)

Replace CAP 

(2)

 and HANDLE 

(1)

. Check flow.

Summary of Contents for COLONY SOFT 2175.503

Page 1: ...E CONTROL LAVATORY FAUCET WITH SPEED CONNECT DRAIN INSTALLATION INSTRUCTIONS 2175 503 Adjustable Wrench Screwdriver Channel Locks Tubing Cutter Plumbers Putty or Caulking Certified to comply with ANSI...

Page 2: ...AY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that WHITE...

Page 3: ...1 HOT COLD FERRULE COMPRESSION NUT COUPLING NUT WITH FAUCET COUPLING NUT ON FLEX SUPPLIES FLEXIBLE SUPPLIES 1 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION CONNECTION 2 3 4 P TRAP NOTE FLEXIBLE SUPPLIES O...

Page 4: ...tal scalding To set the maximum hot water temperature of your faucets all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP Use a flat blade screwdriver or your fingers to pull up and...

Page 5: ...n as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2...

Page 6: ...acing outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete...

Page 7: ...m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1200 M913208 007A SPONGE WASHER M962551 0070A CAM ASSEMBLY M962431 0070A DRAIN MOUNTING KI...

Reviews: