American Standard COLONY SOFT 2175.503 Installation Instructions Manual Download Page 3

- 3 -

    

7

8

•  Thread CABLE CONNECTOR 

(1)

 clockwise 

onto DRAIN BODY CONNECTION 

(2)

 and 

hand tighten. 

Fig. A.

 

Your new POP-UP DRAIN installation is 
now complete. 

Fig. B.

 

Note: 

Tail piece on pop-up drain is  

1-1/4" O.D. 

Fig. B.

•  Operate LIFT KNOB 

(1) 

to verify that STOPPER 

(2)

 opens and 

closes.  

Note:

 If STOPPER

 (2)

 does not open and close properly then 

refer to the “troubleshooting section” of these instructions.

CHECK OPERATION OF POP-UP

MAKE WATER SUPPLY AND WASTE CONNECTIONS

ATTACH CABLE CONNECTOR

6

M968882 Rev. 1.7 (11/17)

Fig.

 

A.

2

1

1-1/4” O.D.

Fig.

 

B.

2

1

HOT

COLD

FERRULE

COMPRESSION

NUT

COUPLING

NUT WITH 

FAUCET

COUPLING

NUT ON FLEX

SUPPLIES

FLEXIBLE

SUPPLIES

1

3/8 O.D.

BULL-NOSE

RISERS

3/8 COMPRESSION

CONNECTION

2

3

4

“P” TRAP

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT  
INCLUDED AND MUST BE PURCHASED SEPARATELY.

•  Connect water supply to INLET SHANKS 

(1)

 with 1/2" IPS 

FLEXIBLE SUPPLIES 

(2)

 or 3/8" O.D. BULL-NOSE RISERS 

(3)

Use adjustable wrench to tighten connections. Do not over 
tighten. Be careful not to kink copper supply when bending. 
Use tubing cutter to cut to proper length.

•  Connect HOT water supply to inlet of left SHANK and COLD 

water supply to right SHANK using sealant, appropriate 
connectors, and COUPLING NUTS.

•  Connect 1-1/4" O.D. TAILPIECE 

(4)

 on POP-UP DRAIN  

to 

“p” trap

.

Summary of Contents for COLONY SOFT 2175.503

Page 1: ...E CONTROL LAVATORY FAUCET WITH SPEED CONNECT DRAIN INSTALLATION INSTRUCTIONS 2175 503 Adjustable Wrench Screwdriver Channel Locks Tubing Cutter Plumbers Putty or Caulking Certified to comply with ANSI...

Page 2: ...AY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that WHITE...

Page 3: ...1 HOT COLD FERRULE COMPRESSION NUT COUPLING NUT WITH FAUCET COUPLING NUT ON FLEX SUPPLIES FLEXIBLE SUPPLIES 1 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION CONNECTION 2 3 4 P TRAP NOTE FLEXIBLE SUPPLIES O...

Page 4: ...tal scalding To set the maximum hot water temperature of your faucets all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP Use a flat blade screwdriver or your fingers to pull up and...

Page 5: ...n as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2...

Page 6: ...acing outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete...

Page 7: ...m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1200 M913208 007A SPONGE WASHER M962551 0070A CAM ASSEMBLY M962431 0070A DRAIN MOUNTING KI...

Reviews: