- 3 -
7
8
• Thread CABLE CONNECTOR
(1)
clockwise
onto DRAIN BODY CONNECTION
(2)
and
hand tighten.
Fig. A.
Your new POP-UP DRAIN installation is
now complete.
Fig. B.
Note:
Tail piece on pop-up drain is
1-1/4" O.D.
Fig. B.
• Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and
closes.
Note:
If STOPPER
(2)
does not open and close properly then
refer to the “troubleshooting section” of these instructions.
CHECK OPERATION OF POP-UP
MAKE WATER SUPPLY AND WASTE CONNECTIONS
ATTACH CABLE CONNECTOR
6
M968882 Rev. 1.7 (11/17)
Fig.
A.
2
1
1-1/4” O.D.
Fig.
B.
2
1
HOT
COLD
FERRULE
COMPRESSION
NUT
COUPLING
NUT WITH
FAUCET
COUPLING
NUT ON FLEX
SUPPLIES
FLEXIBLE
SUPPLIES
1
3/8 O.D.
BULL-NOSE
RISERS
3/8 COMPRESSION
CONNECTION
2
3
4
“P” TRAP
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
• Connect water supply to INLET SHANKS
(1)
with 1/2" IPS
FLEXIBLE SUPPLIES
(2)
or 3/8" O.D. BULL-NOSE RISERS
(3)
.
Use adjustable wrench to tighten connections. Do not over
tighten. Be careful not to kink copper supply when bending.
Use tubing cutter to cut to proper length.
• Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
• Connect 1-1/4" O.D. TAILPIECE
(4)
on POP-UP DRAIN
to
“p” trap
.