background image

- 11 -

1.感应距离默认为

70±5cm 

4.将磁铁移开感应窗口;

6.新的感应距离已成功设定;(见图c.)

5.等待红色

区域走开;

2.将目标物体放置于目标距离处或人站立在目标距离的位置;
  (见图a.)

3.将磁铁(用户自备)靠近感应窗口直至红色

LED

灯开始闪烁;

  

(见图b.)

感应距离调节(如果需要)

Sensor Zone Calibration (If required)

1. Sensor detection zone is set at 70±5cm by default.

4. Remove magnet away from sensor window.

5. Remove target object, or stand away from sensor detection zone 

    once red LED stops flashing.
6. New sensor distance is successfully calibrated. (See Fig.c)

2. Place target or stand at the target distance.

3. Place magnet near sensor window until the red LED starts flashing.

    (See Fig.b)

New sensor distance 

Sensor window

Target distance 

Sensor window

Sensor window

Magnet (self-provided)

磁铁(自备)

(See Fig.a)

Fig. a

Fig. b

Fig. c

感应窗口

目标距离

新感应距离

感应窗口

感应窗口

 a.

 b.

 c.

LED

灯停止闪烁,即可把目标物体移开感应范围或人从感应

Summary of Contents for CCAS6519-3110410C0

Page 1: ...Customer approved by QA approval by Material Size Print Color Drawing No Rev Sheet No installation manual Lynbrook WH urinal Lilian 10 14 2020 Paper 80g A4 Gray Black 730 07 0004 A 1 A4 paper Plastic...

Page 2: ...1 Aug 20 Rev 01 CCAS6519 3110410 CCAS6519 3120410 x4 x1 x1 x2 x1 x1 x1 x2 x1 x1 x1 x1 x2 x1 x1 x1 x2 x1 F0 C0 M0 P0 X X X CCAS6519 3110410C0 F0 M0 P0 CCAS6519 3120410C0 F0 M0 P0...

Page 3: ...2 1a 1b 2 3 480 40 180 135 550 480 40 40 550 826 480 6 CCAS6519 3110410 CCAS6519 3120410 L L N N Celling 550 L N L N...

Page 4: ...3 4 5 6 7 8 9 495 165 6 10mm...

Page 5: ...4 10 11 12 13 14a 14b CCAS6519 3110410 CCAS6519 3120410 1 2 3...

Page 6: ...5 16a 15a 16a 16b 17 18 15b CCAS6519 3110410 CCAS6519 3120410 CCAS6519 3110410 CCAS6519 3120410 2...

Page 7: ...C1 CN511PU0000002 CC1 CN511PU0000007 CC1 CN511P9L317300 CC1 CN511MS0000002 CC1 CN511PU0000003 CC1 CN511PU0000005 CC1 CN511MC0000001 CC1 CN511PU0000004 CC1 CN511MSB317237 CCAS6519 3110410 F0 C0 M0 P0 X...

Page 8: ...7 CCAS6519 3120410 CC1 CN511PU0000002 CC1 CN511MS0000002 CC1 CN511PU0000004 CC1 CN511PU0000003 CC1 CN511PU0000006 CC1 CN511PU0000007 CC1 CN511MSB317237 CC1 CN511P9L317300 CC1 CN511MC0000001...

Page 9: ...age like cigarette end chewing tissue etc The vitreous china product is heavy and fragile Be careful when handling so as to avoid damage or water leakage Measurements in this manual is in Millimeters...

Page 10: ...cceptable Water Temperature 1 C 45 C Detect Time 3 Seconds Flush Time one time flush about 3 3s after usage Flush Volume 0 5L Static 0 17MPa and 0 55MPa average value Environment Protect Urinal will f...

Page 11: ...n the sensor zone for 3s for sensor to detect user Flushing will commence 2s after user leaves position and flushing will last 3 3s 4 Once steps 1 to 3 are completed the urinal is in good working orde...

Page 12: ...stand away from sensor detection zone once red LED stops flashing 6 New sensor distance is successfully calibrated See Fig c 2 Place target or stand at the target distance 3 Place magnet near sensor w...

Page 13: ...open entirely b The filters are blocked c Low water pressure d Water flow is disrupted due to twisted or dented water pipes a Battery run out b The cables are cut off c The solenoid and diaphram is b...

Page 14: ...d don t forget to turn on the water supply when finished 1 Take off the flush valve assembly by loosen the screws at the bottom of the urinal 2 Use hex wrench to close stop valve clockwise until it ca...

Reviews: