background image

Speed Connect™ Drain

Troubleshooting Guide

1

2

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

RE-ATTACH

DISCONNECT

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:
     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

A.

REMOVE
CAM CAP

REMOVE
CAM

Fig.

 

D.

Fig.

 

F.

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection 

(2)

 by threading the Cable Connector 

(1)

 clockwise onto the

Drain Body Connection 

(2)

 and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

5

Fig.

 

B.

1

DOWN

STOPPER

Fig.

 

C.

Fig.

 

E.

M 9 6 8 7 9 7   R e v. 1 . 8

Summary of Contents for CADET 8115F

Page 1: ...ations on purchasing your American Standard faucet with the Speed Connect Drain a feature found only on American Standard faucets Speed Connect Drain 1 3 of the parts installs in 1 3 of the time No to...

Page 2: ...COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A 2 REAR OF SINK 4 5 6 3 1 SINK DRAIN HOLE FLAT SIDE OF GASKET MUST FACE DOWN 1 2 Fig A 2 1 FLAT SIDE OF GRAY LOCKNUT MUST FACE UP INSTA...

Page 3: ...LIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY HOT COLD FERRULE COMPRESSION NUT COUPLING NUT WITH FAUCET COUPLING NUT ON FLEX SUPPLIES FLEXIBLE SUPPLIES 1 3 8 O D BULL NOSE RIS...

Page 4: ...9 4 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOT...

Page 5: ...slowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain F...

Page 6: ...astic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop...

Page 7: ...s METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE UNTHREAD FLANGE STOPPER WHEN DRAIN IS REMOVED FROM ABOVE SINK WHEN DRAIN IS RE...

Page 8: ...070A ATTACHMENT NUT M922880 0020A M922880 2950A AERATOR M950158 0020A M950158 2950A LIFT ROD M918506 0070A CARTRIDGE SCREWS A951470 0070A CARTRIDGE M907301 0020A M907301 2950A CAP M962133 0020A M96213...

Reviews: