background image

M968583

1a

INSTALL FAUCET WITHOUT ESCUTCHEON PLATE
(4101.115 with soap dish)   (4101.350 less soap dish)

Assemble RUBBER WASHER 

(5)

, BRASS WASHER 

(6)

 and threaded LOCKNUT 

(7)

 onto SHANK 

(4)

 from underside

of sink or mounting surface. Hand tighten LOCKNUT 

(7)

 and check that rotation of HANDLE 

(8)

 from HOT to COLD

is centered.
Use a screwdriver to tighten SCREWS 

(9)

 on LOCKNUT 

(7)

. Work your way around LOCKNUT 

(7)

, tightening  the

SCREWS 

(9)

 slightly each time until all are snug to ensure even pressure.

Insert SEAL WASHER 

(1)

 into ESCUTCHEON 

(2). 

Place ESCUTCHEON 

(2)

 onto sink or mounting surface.

 

Insert supply

TUBES 

(3)

 and SHANK 

(4)

 through ESCUTCHEON 

(2)

 and mounting surface.

Make sure slot in fitting base aligns with

tab on

 ESCUTCHEON 

(2). Figure 1.

HOT

COLD

2

MAKE WATER SUPPLY CONNECTIONS

Turn off hot and cold water supplies before beginning.

Push HOSE END 

(1)

 with compression fitting onto COPPER TUBE 

(2)

 Make sure

HOSE and COPPER TUBE are fully engaged (approx.1/2" engagement). Use adjustable
wrench to tighten connections. Do not over tighten.

Connect FLEXIBLE SUPPLIES 

(3)

 directly to wall supplies. Connection on fitting

supplies are 3/8" compression. Connect left supply (Marked with a Red Stripe)
to Hot and right supply to Cold wall supply. Use adjustable wrench to tighten
connections. Do not over tighten.

Faucet supplies are 24-1/2" long from faucet base.

Note:

 If additional supply length is required, installer must purchase

those parts separately.

Important:

 If SUPPLY HOSES (3) are too long, loop as illustrated to avoid kinking.

Assemble RUBBER WASHER 

(5a)

, BRASS WASHER 

(6a)

, and threaded LOCKNUT 

(7a)

 onto SHANK 

(11)

 from underside

of sink or mounting surface. Hand tighten LOCKNUT 

(7a)

. Use a screwdriver to tighten SCREWS 

(9a)

 on LOCKNUT 

(7a)

the same as fitting installation above.

Install SPOUT ASSEMBLY:

 

Insert SEAL WASHER 

(1a)

 into ESCUTCHEON 

(2a). 

Insert SPOUT HOSE 

(10)

 and SHANK 

(11)

through ESCUTCHEON 

(2a)

 and mounting surface. Make sure slot in spout base aligns with tab on ESCUTCHEON 

(2a).

Figure 2.

Install SPRAY HOLDER: 

Insert SPRAY HOLDER 

(11)

 into ESCUTCHEON 

(12). 

Insert SEAL 

(14) 

into underside of 

ESCUTCHEON 

(12)

. From underside of sink or mounting surface thread LOCKNUT 

(13)

 onto SPRAY HOLDER 

(11)

shank and tighten. 

 

 

ALIGN SLOT

AND TAB

SLOT

RED STRIPE

1/2"
ENGAGEMENT

TAB

2a

1a

11

5a

6a

9a

Figure 1

Figure 2

5

6
7
9

8

ALIGN SLOT 

AND TAB

SLOT

TAB

13

2
1

3

2

1

3

4

12

11

14

10

7a

Summary of Contents for Arch Control Kitchen Faucet 4101.301

Page 1: ...of sink or mounting surface thread LOCKNUT 12 onto SPRAY HOLDER 11 shank and tighten Installation with DECK ESCUTCHEON Apply a light bead of plumbers putty to underside of ESCUTCHEON 1 if mounting surface is uneven Place ESCUTCHEON 1 onto sink or mounting surface with large opening to the right as shown Insert supply HOSES 2 and SHANK 3 through ESCUTCHEON 1 and mounting surface Make sure slot in f...

Page 2: ...plies Connection on fitting supplies are 3 8 compression Connect left supply Marked with a Red Stripe to Hot and right supply to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten Faucet supplies are 24 1 2 long from faucet base Note If additional supply length is required installer must purchase those parts separately Important If SUPPLY HOSES 3 are too long loop as...

Page 3: ...OR LEAKS 4 3 4 1 7 3 CONNECT SPRAY HOSE AND SPOUT HOSE Feed HAND SPRAY HOSE 1 through SPRAY HOLDER 2 Use wrench to tighten COUPLING NUT 3 on SPRAY HOSE 1 to SIDE SPRAY CONNECTION 4 on fitting Make sure SEAL WASHER 5 is installed in COUPLING NUT 6 Connect threaded end of HOSE 7 to SPOUT HOSE COUPLING NUT 6 from fitting Use wrench to tighten 2 6 5 1 ...

Page 4: ... several times from off to on Do not apply excessive force Remove INDEX BUTTON 1 loosen HANDLE SCREW 2 and remove HANDLE 3 Unthread ESCUTCHEON CAP 4 Unthread three MOUNTING SCREWS 5 Lift CARTRIDGE 6 off MANIFOLD 7 and remove CARTRIDGE SEALS 8 Place SEALS 8 into CARTRIDGE PORTS 6a Replace ESCUTCHEON CAP 4 HANDLE 3 tighten HANDLE SCREW 1 and install INDEX BUTTON 2 Test fitting Clean MANIFOLD 7 CARTR...

Page 5: ... n c 2 0 0 8 HOT LINE FOR HELP 4101 301 ARCH M962725 YYY0A ESCUTCHEON KIT 4101 301 4101 301 M923651 YYY0A SPRAY HOLDER M923276 0070A SUPPLY HOSE M907610 YYY0A SPRAY ESCUTCHEON 4101 301 M918521 0070A CARTRIDGE SCREWS A951470 0070A CARTRIDGE M962716 0070A BUTTON AND SCREW KIT M907305 YYY0A CARTRIDGE COVER M962715 YYY0A AERATOR CHROME STAINLESS STEEL 002 075 Replace the YYY with appropriate finish co...

Reviews: