Energy Saving Factory Pre-Program
The 302 and 303 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this
program suits your needs, simply set the thermostat clock and press the RUN key.
The table below shows the factory set heating and cooling schedule for all days of the week.
* Wake Up
(Morning)
Leave For Work
(Day)
* Return Home
(Evening)
Go To Bed
(Night)
Heating Program
6:00 AM
70°F
8:00 AM
62°F
5:00 PM
70°F
10:00 PM
62°F
Cooling Program
6:00 AM
75°F
8:00 AM
83°F
5:00 PM
75°F
10:00 PM
78°F
*
You can eliminate these two program periods in the configuration menu (reference #5) if the building is occupied all day.
Day period will change to 6:00 AM and 70° and can be programmed as required.
10. Planning Your Program – Important
The Heating and Cooling Program schedules provided allow you to pencil in your own program times and temperatures.
The 302 and 303 Thermostats come configured for 7 day programming and can also be configured for 5+1+1 programming (see
configuration section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your own times
and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
•
In Heating, lower temperatures will save energy.
•
In Cooling, higher temperatures will save energy.
•
If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature.
9.3 Enter the Heating Program
1. Press the Menu key and then press Set Schedule.
2. Press SYSTEM key to select “Heat” in the system switch
area indicating the active mode being programmed. You
can switch to the other mode by pressing the system switch
at any time.
3. The top of the display will show the day(s) being
programmed. The time and set at temperature are also
displayed. “Morning” will also be displayed to indicate the
period.
4. Press
or
key to change the temperature to your
selected temperature for the 1st heating period (Morning).
5. Press or key to adjust the start time for period.
The time will change in 15 minute increments.
6.
Press FAN to select Auto or Prog.
7.
After you have set the time and the temperature for the
period to begin, press Set Schedule to advance to the next
program period.
8.
Repeat steps 2 through 6 until all of the program times and
temperatures are set for all program periods on that day.
9.
Press “Advance Day” to change to the next day and
repeat steps 2 through 8.
10.
When programming is complete and all of the times and
temperatures match your desired heating schedule, press
11.
Run Schedule. The thermostat will now run your program
9.4 Enter the Cooling Program
1.
Press the SYSTEM key until the
“Cool”
icon appears.
2.
Follow
Enter Heating Program
instructions for
enteringcooling times and temperatures.
9.5 Automatic Schedule
Auto Schedule Heat is a fast way to program all the heating
temperatures during the day to a comfortable temperature
and then lower the temperature 6° at night. Auto Schedule
Cool will program all of the cooling time periods to the same
temperature.
Note: Auto Schedule
is available only when the thermostat
is first powered on, after the thermostat has been reset, or
anytime you turn
AS
on in the Configuration Menu (item 17
AS Heat
or 18
AS Cool
). After use in heating and cooling,
Auto Schedule
on the display will change to
Humidity
.
Heating Example:
1.
In Heat mode, press Auto Schedule once.
2.
Press or
to select a comfortable day time temperature
(example 72°).
3.
Press Auto Schedule again. Your thermostat is now
programmed for 72° from 6:30 AM until 10:30 PM at 72°. At
10:30 PM, your thermostat will set back 6° to 66°.