9
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR HOUSING
(6)
. (Turn counter-clockwise).
Remove AERATOR INSERT
(3)
from AERATOR HOUSING
(6)
.
Operate both HANDLES
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
and AERATOR HOUSING
(6)
.
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(5)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
11
“P” TRAP
REMOVE
WASTE
OUTLET
4
SERVICE
M 9 6 8 6 3 3 Rev. 1. 3
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
10
90˚
6
3
1
If Faucet Drips Proceed As Follows:
Turn VALVE in OFF position.
Push in INDEX BUTTON
(1).
Remove HANDLE SCREW
(2)
, and pull HANDLE
(3)
off of
ADAPTOR
(4)
.
Turn VALVE to OFF position. Pull out INDEX BUTTON
(1)
.
To change direction of handle
rotation, proceed as follows:
Pull ADAPTOR
(4)
off VALVE STEM
(5)
and turn 90˚ in a way that
flat in ADAPTOR
(4)
catches a different flat on VALVE STEM
(5)
.
If spout drips, operate HANDLES
(1)
several times from
OFF to ON position. Do not force-handles turn only 90˚.
AERATOR
(6)
may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR
(6)
and rinse clean.
See step 9 above.
Reinstall ADAPTER
(4)
, HANDLE
(3)
and HANDLE SCREW
(2)
.
4
5
FLAT
2
3
6