C. UNIT INSTALLATION
UPFLOW
▲
CAUTION
!
When unit is installed in non-ducted applications,
BAYPLNM120 must be used.
a. Before installing unit, remove thumbscrews to
the filter panel. Carefully remove the COLLEC-
TION CELL by grasping the leading edge of the
frame. See Figure 6. Set aside in a safe place un-
til the unit is set in place and ready to start up.
b. Use a 5/16" nutdriver to remove the screws hold-
ing the FIELD CHARGER retainer and take out
both. Slightly lift the FIELD CHARGER and care-
fully remove. Set aside in a safe place until the
unit is set in place and ready to start up. See Fig-
ures 7 and 8.
c. Position unit to remove the bottom protector
plate by laying the unit on its back. Use a flat
blade screwdriver between the protector plate
and the unit to pry apart. See Figure 9. Gently
pull the plate towards the front of the unit to re-
move.
Steam and Flow-through Fan Power Duct-
mounted Humidifiers
Follow the humidifier installation instructions.
These should only be installed on the supply air
side of the system.
Other Duct Mounted Humidifiers are Not rec-
ommended for installation with the air
cleaner.
21. Unit installation must include either a return air
duct or grill that prevents accidental access to pins.
For upflow open air intake applications that do not
have a grill or return air duct, installation will re-
quire the use of either
BAYPLNM120, TASB215,
TASB235, or TASB260
depending on cabinet size.
TASB
accessories can be purchaed from:
Miami Tech Inc.
3611 NW 74 Street
Miami, Florida 33147
Phone: 800-339-2290
Fax: 305-693-6152
www.miamitech.com
TASB215
for use with 21.5" cabinets 2/4TEE3D31
TASB235
for use with 23.5" cabinets 2/4TEE3D37
TASB260
for use with 26.0" cabinets 2/4TEE3D40,49,
and 65
22. A PRE-FILTER is not required to be installed with
the air handler containing a Whole House Air
Cleaner. If the use of a PRE-FILTER is desired, it
must be installed at least 6" away from the Whole
House Air Cleaner.
B. TWO PIECE CABINET DISASSEMBLY
(OPTIONAL)
NOTE: For easier installation into tight areas, the 4
and 5 ton air handlers can be disassembled and reas-
sembled after moved to an attic or other space.
Steps for disassembly and reassembly (See Figures 4
and 5)
1.
Disconnect wiring.
2.
Remove center bracket.
3.
Remove blower assembly.
4.
Remove coil.
5.
Cut foil tape - minimum 3" foil tape.
6.
Remove top 8 screws. See Figure 3.
7.
Lift upper section.
8.
Set air handler in place.
9.
Attach screws - insure gaskets are aligned
along flange.
10.
Use foil tape to seal - use minimum 3" foil tape.
11.
Insert coil.
12.
Reinstall blower assembly.
13.
Reinstall center bracket.
14.
Reconnect wiring.
NOTE: In Downflow, remove coil before blower by
reversing steps 4 and 5.
2 Piece Wrapper Spear
Figure 5
Figure 4 Closeup of Spear Locations
1
2
3
4
SCREWS 5-8