background image

 

                                                                     OWNERS MANUAL

 

                                                                                                        

                                                                                                                                                  

 

 

 

 

 

     TESTING YOUR WALK-IN TUB BEFORE INSTALLATION 

 
 

1.  All American Standard® walk-in baths are 100% water tested at the factory and have passed inspection. 

Transportation and mishandling may loosen fittings and cause leaks.  It is therefore necessary to 

test the 

bathtub while there is access to all sides of the bath.

 

 
2.  This unit should be both static and operationally tested with water.  It is best to test the unit outside by 

filling with a garden hose. 

 

a.

 

Place the tub on a completely flat surface in an area where it may be drained after testing. 

 

b.

 

Using a clean rag and warm water wipe down seal to insure it is free of debris. 

 

c.

 

Seal the drain hole (this can be done with tape) and fill the tub to at least three inches above the 
highest jet, or to the bottom of the safety bar if no jets are present. 

       

d.

 

Allow the water to stand in tub for 10 minutes and then inspect all plumbing and seals for 
leaks. 

 

e.

 

Using appropriately rated three-prong extension cords, all plugged in to separate outlets, 
operate all electrical components (air blower, water pump, and heater if applicable) for another 
10 minutes and inspect for leaks again. Inspect the unions around the pump and heater. 

 

f.

 

 If a leak persists at a union after tightening, it may have been over-tightened or might have a 
displaced O-ring. Disassemble it and make sure the O-ring was seated properly. Do the same if 
a leak persists at the heater. Verify that the heater threads match the pipe threads.  

 

g.

 

Ensure that all jets are open and working (some hydro jets are adjustable for both flow rate and 
direction of flow.  For some jets, the water flow is adjusted by turning either the outside ring or 
the inside nozzle clockwise or counterclockwise. The small jets are not adjustable at the jet but 
can be adjusted by the pump speed or legs only massage. 

 
3.  If the pump/blower/heater does not operate: 
 

a.

 

Check the breaker to ensure that power is on and make sure that any cables connecting the 
control box to the switches and pumps are firmly attached. Check outlet for current by plugging 
in a light or hair dryer. 

b.

 

Ensure the pump/blower is plugged into the control box and the control box is plugged into the 
wall. 

c.

 

If an optional heater is present, check the indicator light on the top of its housing. This light 
will only come on 

while the pump is running

. The heater is dormant when no water flows. 

d.

 

Do not

 run any pumps unless the tub is filled with water to the proper level. Damage due to dry 

operation of pumps is not covered under the ten year warranty. 

 

Failure to perform these tests before installation will make the installer liable for future repair costs. 

Summary of Contents for 2651.110

Page 1: ...WALK IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL...

Page 2: ...now the owner of a walk in bathtub from the most trusted name in plumbing We thank you for your purchase Your American Standard walk in bath is a true investment in your health and peace of mind Cust...

Page 3: ...ES OF THE INSTALLER Page 4 TESTING YOUR TUB BEFORE INSTALLATION Page 5 INSTALLATION PREPARATION Page 6 ELECTRICAL INSTALLATION Page 7 INSTALLATION PROCEDURES Page 8 9 SAFETY INSTRUCTIONS Page 10 OPERA...

Page 4: ...nstallation related if not reported prior to installation Installers are also responsible for damage that occurs once the unit is placed in its niche NOTE Remove all packaging material except for the...

Page 5: ...staller assumes all liabilities for installation procedures Although American Standard has taken reasonable precautions to ensure that the Quick Drain TM is suitable for residential plumbing it is the...

Page 6: ...ion after tightening it may have been over tightened or might have a displaced O ring Disassemble it and make sure the O ring was seated properly Do the same if a leak persists at the heater Verify th...

Page 7: ...ng feet to perfectly level the tub Note It is important that all 5 leveling feet are completely touching the floor and level for the door system to work properly 2 Check to ensure that the drain pipin...

Page 8: ...HE FAUCETS WHIRLPOOL AIR SPA CONFIGURATIONS FOR FACTORY INSTALLED COMPONENTS This section lists the factory installed components of the Whirlpool and or Air Spa Systems Note the required number of cir...

Page 9: ...mmended that the handheld be installed on the corner closest to the wall to prevent water from leaking off the deck and onto the floor 3 Install the optional in line water heater per manufacturer s in...

Page 10: ...uld be installed on the tub before it is placed in the alcove Install the tile flange along all sides of the tub where the wall will be Measure to fit and miter cut the flange corners The flange shoul...

Page 11: ...sciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your doctor before using the bathtub WARNING Risk of personal injury Risk of electric shock do not permit...

Page 12: ...opens and closes jets above the seat which allows you to fill the tub half way and operate the lower whirlpool jets The Legs Massage valve must be closed when filling the tub half way and operating th...

Page 13: ...use 12 There are no user serviceable parts located under the tub PURGE CYCLE All air blowers are equipped with a purge cycle to remove residual water from the lines The cycle will begin approximately...

Page 14: ...r and clean away any hair lint or debris from the cover and housing then remount the cover in place Some suctions are not designed to be removed only suctions that have screws on the cover visible fro...

Page 15: ...anty expressed or implied including any warranty of merchantability or fitness for a particular purpose shall apply after the warranty period described above This warranty does not cover defects or da...

Reviews: