A Ground Fault Interrupter (GFI) shall be used as required by NFPA-70 (National Electric Code), Federal / State / Local laws or 

local ordinances.

•  The required use of a GFI is normally related to the location of a receptacle to any significant sources of water or moisture.

•  American Range will not warranty any problems resulting from GFI outlets which are not installed properly or do not meet 

  the requirements below.

IF THE USE OF A GFI IS REQUIRED, it should be:

•  The receptacle type (breaker type or portable type not recommended).

•  Used with permanent wiring only (temporary or portable wiring not recommended).

•  On a dedicated circuit (no other receptacles, switches or loads in the circuit).

•  Connected to a standard breaker or appropriate size (GFI breaker of the same size not recommended).

•  Rated for class (5mA + 1mA trip current) as per UL 943 standard.

•  In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations).

•  Protected from moisture (water, steam, high humidity) as much as reasonably possible.

Slide-In Cook Tops

Installation Manual

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

3

IMPORTANT -  PLEASE READ AND FOLLOW!

To prevent possible damage to cabinets and cabinet finishes, use only materials 
that will not discolor or delaminate and will withstand temperatures up to 194ºF 
(90ºC).  Heat resistant adhesive must be used if the product is to be installed in 
laminated cabinetry, check with your builder or cabinet supplier to make sure 
that the materials meet these requirements.

WARNING

!

The use of cabinets for storage above the oven may result in potential fire 
or burn hazard.

WARNING

!

To avoid risk of electrical shock, personal injury or death; verify your appliance 
has been properly grounded in accordance with local codes or in absence of 
codes, with the National Electrical Code (NEC).ANSI/NFPA 70 latest edition.

DANGER

!

Summary of Contents for PERFORMER AROBSCT-242GD

Page 1: ...AROBSCT 848 AROBSCT 648GD AROBSCT 648GR AROBSCT 4482GD AROBSCT 448X2GR AROBSCT 448GDGR AROBSCT 660GDGR AROBSCT 6602GD AROBSCT 660X2GR PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA...

Page 2: ...ctrical Gas Locations 12 Electrical Gas Requirements 13 Gas Requirements 14 General Instructions 15 Installation Instructions 15 Installation Steps 16 19 Performance Check List 20 Final Preparation 20...

Page 3: ..._____ Electrical Information ______________________________________ FOR YOUR SAFETY FOR YOUR SAFETY Instruction to be followed in the event the user smells gas should be posted in a prominent location...

Page 4: ...ounded Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages Installation...

Page 5: ...ondition and free from any loose fitting gaskets if applicable in outdoor situations Protected from moisture water steam high humidity as much as reasonably possible Slide In CookTops Installation Man...

Page 6: ...oving Hazard To avoid risk of severe personal injury this appliance requires two or more personnel while handling or moving Possible use of appliance moving devices is recommended WARNING Gas Leak Haz...

Page 7: ...Tops Installation Manual 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5 DIMENSIONS SLIDE IN COOK TOPS Model A In 24 Slide In 23 7 8 30 Slide In 29 7...

Page 8: ...l Width 24 30 36 48 60 Overall Height To top of grate 9 5 16 Overall Depth 29 3 4 Gas Requirements 7 W C Natural 11 LP Gas Manifold Pressure 5 W C Natural 10 LP Electrical Requirements 120VAC 60Hz Sin...

Page 9: ...ve the 36 counter height Within 6 side clearance to combustible vertical surfaces above 36 the maximum wall cabinet depth must be 13 and wall cabinets within this 6 side clearance must be 18 above the...

Page 10: ...de for safe and efficient operation of the hood This is a vented appliance The appliance should not be installed with a ventilation system that blows air downward towards the range This type of ventil...

Page 11: ...e appliance should not be installed with a ventilation system that blows air downward towards the range This type of ventilation system may cause ignition and combustion problems with the gas cooking...

Page 12: ...mericanrange com 10 CLEARANCE DIMENSIONS Cook Top Width A Dimension B Dimension 24 24 30 30 30 36 36 36 42 48 48 54 60 60 66 The gas and electrical supplies should be located in cabinet below the cook...

Page 13: ...9898 toll free www americanrange com 11 Electric and Gas supplies should be located inside the cabinet under the countertop with front acccess to cutoff 12 by 3 1 2 platform cut out at right far corn...

Page 14: ...with a 16 STP2 Power Cord GAS CONNECTION The gas supply service line must be the same size or greater then the inlet line of the appliance This cook top uses a 1 2 ID NPT inlet Sealant on all pipe joi...

Page 15: ...least 1 2 ID NPT in compliance with ANSI Z21 41 and Z21 69 In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 Quick Disconnect devices for use with gas fuel In Massachusett...

Page 16: ...strip by removing the attachment screw Confirm available access to adequate power and gas See Specifications and Electrical Requirements table Fill out page 1 of this manual with requested data Model...

Page 17: ...ual 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 15 INSTALLATION STEPS STEP 1 Slide cook top into the cabinet opening Run power cord from the cook to...

Page 18: ...Manual gas shutoff valve E 3 4 or 1 2 gas supply F Use pipe joint compound To avoid risk of personal injury or death leak test of the appliance must be conducted according to the manufacturer s instr...

Page 19: ...753 9898 toll free www americanrange com 17 INSTALLATION STEPS BURNER PAN STEP 3 Remove the burner pans Cut and discard the shipping ties on the burner base Confirm that burner base is flat on the bur...

Page 20: ...e burner heads on burner bases Align holes in top burner with pins on base of burner for proper capacity operation For locations of burner heads see diagram below Each burner is different by capacity...

Page 21: ...medium large small large large medium medium large small large large medium medium large small large medium large small large medium large small large medium large small large large large medium mediu...

Page 22: ...nel 0 Check knob rotation function for free and smooth turning FINAL PREPARATION Some Stainless Steel parts may have a plastic protective wrap which must be peeled off All Stainless Steel body parts s...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 24: ...d licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified installation mu...