9
CLEARANCE DIMENSIONS
Important:
This cook top comes standard with island trim. There must be a minimum of 6" clearance from rear of cook top to a
combustible wall or 0" clearance to an non-combustible wall.
This is a vented appliance. The appliance should not be installed with a ventilation system that blows air downward
towards the range. This type of ventilation system may cause ignition and combustion problems with the gas cooking
appliance resulting in personal injury or unintended operation.
Air curtain or other overhead range hood, which operates by blowing a downward airflow onto a range, shall not be
used in conjunction with this appliance.
Note:
" minimum with island trim and combustible rear wall. 0" with island trim and non-combustible rear wall.
IMPORTANTWARNING
!
6"
30"
66" min.
TO
72" max.
30" min.