American Range GREEN FLAME RESTAURANT AR-GF Series Owner'S Manual Download Page 8

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

4

Owner’s Manual

      AR-GF Series Ranges

RATING PLATE

  - 

The  information  on  the  rating  plate  defines  the  model, 

serial number, gas type (natural or liquid propane), operating pressures and burner 

BTU ratings.  Keep this information for future reference.  It is essential for proper 

identification of the unit when requesting additional information or factory support.

Appliances must be connected only to the type of gas identified on the rating plate.

WARNING

!

Intertek

3013256

Intertek

MODEL:

SERIAL NO.

AR-GF-36

GAS TYPE: NAT

MAN. PRESS:

IN. W.C.

5.0

XXXXXX-XXX

INPUT-BTU/HOUR/BURNER

CLEARANCES

NON-COMB. COMB.

25,000

BACK

SIDES

0"

0"

4"

12"

FOR USE ONLY ON NONCOMBUSTIBLE NONCOMBUSTIBLE FLOORS

CURB MUST HAVE 2" OVERHANG

INTENDED FOR OTHER THAN HOUSEHOLD USE.

ANSI Z83.11a/CSA 1.8a-2007 Food Service Equipment

OPEN TOP

GRIDDLE

HOT TOP

20,000

*

27,000

SM. OVEN

STD. OVEN

CONV/NV

OVEN

35,000

30,000

ELECTRICAL RATINGS

NOMINAL:      VAC

INNOVECTION:

CONVECTION:

120

PHASE 1

AMP 15

HZ 60

VAC 120

PHASE 1

AMP

HZ 60

3

VAC 120

PHASE 1

AMP

HZ 60

5

GAS CONNECTION

 - 

The single deck oven requires one gas connection; the double deck oven requires two gas connections.  

The gas inlet line size of this appliance is 3/4" NPT.  For proper operation, the gas supply service line must be the same size or 

greater than the inlet line size of the appliance.  

MANUAL SHUT-OFF  VALVE

 - 

A gas pressure regulator and a contractor-supplied shut-off valve must be plumbed in the gas 

service line ahead of the appliance – in a physical location where it can be reached quickly in the event of an emergency.

A

D

C

E

F

G

C

B

B

C

G

F

E

C

D

A

H

NATURAL GAS

LP GAS

A. Gas pressure regulator

B. 90º Street elbow

C. Adapter (must be 3/4" male pipe thread)

D. Flexible connector

E. Manual gas shut-off valve

F. 3/4" gas supply

G. Use pipe-joint compound

A. Gas pressure regulator

B. 90º Street elbow

C. Adapter (must be 3/4" I.O. male pipe thread)

D. Flexible connector

E. Manual gas shut-off valve

F. 3/4" gas supply

G. Use pipe-joint compound

H. Step down regulator

The gas pressure regulator must be installed in the gas line – failure to install a pressure regulator will void the equipment warranty.  The 

regulators supplied with ranges have 3/4" NPT connections; the regulator is adjusted at the factory for 5" W.C (water column) manifold 

gas pressure (natural gas) or 10" W.C. manifold gas pressure for propane gas operation. 

Before connecting the regulator, check the incoming line pressure – as these regulators can only withstand a maximum inlet pressure 

of 14" W.C. (1/2 PSI); exceeding this pressure will damage them.  Visually double check any installer-supplied intake pipes and/or blow 

them out using compressed air to clear any dirt or debris, threading chips, or other foreign matter – before installing a service line.  

Those particles will clog gas orifices when gas pressure is applied.  Compounds used on threaded joints of this appliance piping must be 

resistant to the action of NG and LP gas and provide a gas tight seal to prevent leaks.  If the gas supply line pressure is greater than this 

amount, a step-down regulator will be required.  A gas flow direction arrow is cast into the body of the regulator to minimize installation 

error – it should point downstream to the appliance.  The blue air vent cap on the top of the regulator is part of the regulator and 

should not be removed.

Any adjustment to the regulator must be 

made only by qualified and licensed service 

personnel with the proper calibrated test 

equipment. Gas connections should be 

performed by a qualified licensed contractor.

Rating Plate

Summary of Contents for GREEN FLAME RESTAURANT AR-GF Series

Page 1: ...NT SERIES RANGES AR GF SERIES PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 2012 American...

Page 2: ...________________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ______...

Page 3: ...p the unit basic operating instructions and how to maintain that just like brand new appearance and performance over years of day to day use If you should encounter any sort of problem turn to the sec...

Page 4: ...ric Standard Codes 5 Casters 6 Leveling 6 Electrical Connection 6 Gas Connection 7 Pressure Regulator 7 Gas Requirements 7 Test Joints 7 Couplings Connectors Casters 7 RANGE START UP PROCEDURE 8 TYPIC...

Page 5: ...ctions for local inspectors and for future use The included Anti Tip Device must be installed prior to operation WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 6: ...rtation company assumes full responsibility for the safe delivery upon acceptance of the equipment If you receive a damaged product immediately contact your delivery company your dealer your builder o...

Page 7: ...ance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B149...

Page 8: ...re regulator B 90 Street elbow C Adapter must be 3 4 male pipe thread D Flexible connector E Manual gas shut off valve F 3 4 gas supply G Use pipe joint compound A Gas pressure regulator B 90 Street e...

Page 9: ...a company which either in person or through a representative are engaged in and responsible for the installation of electrical wiring from the electric meter main control box or service outlet to the...

Page 10: ...hing them to appropriate atmospheric conditions We recommend that adjustments and calibrations are performed upon installation to assure proper operation of the unit and avoid possible problems caused...

Page 11: ...ne gas connection is 3 4 N P T minimum 3 4 diameter flex line 0 LP gas inlet pressure to measure 11 to 14 W C 0 A step down regulator is required at the LP Propane source to limit a pressure maximum o...

Page 12: ...is best they not contribute to the taste or odor of your first oven cooking experience OVEN BURN OFF PROCEDURE Turn on the kitchen ventilating hood Light the oven according to the instructions in the...

Page 13: ...es TYPICAL MODEL PARTS IDENTIFICATION OVEN THERMOSTAT RIGHT FRONT RIGHT REAR REAR CENTER FRONT CENTER LEFT FRONT LEFT REAR BURNER ON LIGHT FAN SWITCH IF SO EQUIPPED CONVECTION INNOVECTION ON BURNER OF...

Page 14: ...Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been developed to assure proper installation of your oven To validate...

Page 15: ...Strong drafts spills and general grime influence the operation of the automatic re ignition system a clean system will generally function better than a dirty system Periodically remove any materials...

Page 16: ...ARVIEW SHOWN 1 Slide hi shelf assembly from top with mounting channels going inside the body sides 2 Set on top of support brackets and screw to body sides at rear MOUNTING CHANNEL HI SHELF ASSY RANGE...

Page 17: ...e moisten a soft scrub cloth adding a drop of mild degreaser dish soap to create a soapy lather and wipe the griddle from left to right Clean in rows from the top to the bottom taking time to wash the...

Page 18: ...ing process Periodic 1 Remove burner assembly and clean with warm water and wire brush Make sure the tiny burner ports are not clogged 2 Remove griddle plate assembly and thoroughly scrape and clean t...

Page 19: ...025 36 Trim Front AR 6 7 1092 36 Tray Grease Collector 8 1194 Assy Lending Ledge 9 71475A Valve Cover Assy 10 A17036 Grate Top Singles 11 A31025 Rack AR 6 12 A99500 Door Assy AR 6 13 BASE CELL ASSY Ba...

Page 20: ...chlorine compounds in some cleaners are corrosive to Stainless Steel Griddle Clean griddle plate with half and half mixture of soda water and vinegar Rinse with warm water Use plastic spatulas and spo...

Page 21: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 22: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 24: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: