![American Range GREEN FLAME RESTAURANT AR-GF Series Owner'S Manual Download Page 8](http://html1.mh-extra.com/html/american-range/green-flame-restaurant-ar-gf-series/green-flame-restaurant-ar-gf-series_owners-manual_2925069008.webp)
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
4
Owner’s Manual
AR-GF Series Ranges
RATING PLATE
-
The information on the rating plate defines the model,
serial number, gas type (natural or liquid propane), operating pressures and burner
BTU ratings. Keep this information for future reference. It is essential for proper
identification of the unit when requesting additional information or factory support.
Appliances must be connected only to the type of gas identified on the rating plate.
WARNING
!
Intertek
3013256
Intertek
MODEL:
SERIAL NO.
AR-GF-36
GAS TYPE: NAT
MAN. PRESS:
IN. W.C.
5.0
XXXXXX-XXX
INPUT-BTU/HOUR/BURNER
CLEARANCES
NON-COMB. COMB.
25,000
BACK
SIDES
0"
0"
4"
12"
FOR USE ONLY ON NONCOMBUSTIBLE NONCOMBUSTIBLE FLOORS
CURB MUST HAVE 2" OVERHANG
INTENDED FOR OTHER THAN HOUSEHOLD USE.
ANSI Z83.11a/CSA 1.8a-2007 Food Service Equipment
OPEN TOP
GRIDDLE
HOT TOP
20,000
*
27,000
SM. OVEN
STD. OVEN
CONV/NV
OVEN
35,000
30,000
ELECTRICAL RATINGS
NOMINAL: VAC
INNOVECTION:
CONVECTION:
120
PHASE 1
AMP 15
HZ 60
VAC 120
PHASE 1
AMP
HZ 60
3
VAC 120
PHASE 1
AMP
HZ 60
5
GAS CONNECTION
-
The single deck oven requires one gas connection; the double deck oven requires two gas connections.
The gas inlet line size of this appliance is 3/4" NPT. For proper operation, the gas supply service line must be the same size or
greater than the inlet line size of the appliance.
MANUAL SHUT-OFF VALVE
-
A gas pressure regulator and a contractor-supplied shut-off valve must be plumbed in the gas
service line ahead of the appliance – in a physical location where it can be reached quickly in the event of an emergency.
A
D
C
E
F
G
C
B
B
C
G
F
E
C
D
A
H
NATURAL GAS
LP GAS
A. Gas pressure regulator
B. 90º Street elbow
C. Adapter (must be 3/4" male pipe thread)
D. Flexible connector
E. Manual gas shut-off valve
F. 3/4" gas supply
G. Use pipe-joint compound
A. Gas pressure regulator
B. 90º Street elbow
C. Adapter (must be 3/4" I.O. male pipe thread)
D. Flexible connector
E. Manual gas shut-off valve
F. 3/4" gas supply
G. Use pipe-joint compound
H. Step down regulator
The gas pressure regulator must be installed in the gas line – failure to install a pressure regulator will void the equipment warranty. The
regulators supplied with ranges have 3/4" NPT connections; the regulator is adjusted at the factory for 5" W.C (water column) manifold
gas pressure (natural gas) or 10" W.C. manifold gas pressure for propane gas operation.
Before connecting the regulator, check the incoming line pressure – as these regulators can only withstand a maximum inlet pressure
of 14" W.C. (1/2 PSI); exceeding this pressure will damage them. Visually double check any installer-supplied intake pipes and/or blow
them out using compressed air to clear any dirt or debris, threading chips, or other foreign matter – before installing a service line.
Those particles will clog gas orifices when gas pressure is applied. Compounds used on threaded joints of this appliance piping must be
resistant to the action of NG and LP gas and provide a gas tight seal to prevent leaks. If the gas supply line pressure is greater than this
amount, a step-down regulator will be required. A gas flow direction arrow is cast into the body of the regulator to minimize installation
error – it should point downstream to the appliance. The blue air vent cap on the top of the regulator is part of the regulator and
should not be removed.
Any adjustment to the regulator must be
made only by qualified and licensed service
personnel with the proper calibrated test
equipment. Gas connections should be
performed by a qualified licensed contractor.
Rating Plate