background image

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

1

Owner’s Manual

ARMG,  ARTG,  AEMG,  AETG,  

ACCG,  ARGB,  ARTY

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with 

the functions of the equipment and experienced with state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar 

with the functions of the equipment.
Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range equipment.

The gas pressure regulator provided with the equipment must be installed when the appliance is connected to the gas supply. 
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquids, brooms, rags, etc. 
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air and adequate clearance for 

air openings into the combustion chamber, for proper combustion and ventilation.  For proper operation of the appliance, do not 

obstruct the flow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988 

(or latest addenda).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of 

that system in excess of 1/2 PSI.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure 

testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least 3/4” NPT.

ShIPPING DAMAGE CLAIM PROCEDURE
 
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory.  The transportation company 
assumes full responsibility for the safe delivery upon acceptance of the equipment. 

If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer.  Do not 
install or attempt to operate a damaged appliance.

1.  Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making 
     the delivery.
2.  File claim for damages immediately regardless of the extent of damages.
3.  For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and file  
  a "Concealed Damage" claim with them.  This should be done within fifteen (15) days from the date that delivery  
  is made to you.  Retain the shipping container for inspection.

IMPORTANT

INSTALLATION INSTRUCTIONS

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of California to 

cause cancer or reproductive harm.  California law requires businesses to warn customers of potential exposure to such substances.  

To minimize exposure to these substances, always operate this unit according to the Owners Manual, ensuring you provide proper 

ventilation when cooking with gas.

Summary of Contents for ACCG

Page 1: ...898 toll free www americanrange com OWNER S MANUAL FOR PROFESSIONAL SERIES COUNTERTOP GRIDDLES MODEL NUMBERS ARMG ARTG AEMG AETG ACCG ARGB ARTY PROFESSIONAL QUALITY COOKING EQUIPMENT DESIGN CLASS FUNC...

Page 2: ..._____________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date __________ Gas Ty...

Page 3: ...to maintain that just like brand new appearance and performance over years of day to day use If you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for...

Page 4: ...afety Information 1 Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Clearances 3 Operating 3 Check fo...

Page 5: ...ply piping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve durin...

Page 6: ...red A gas flow direction arrow is cast into the body of the regulator to minimize installation error it should point downstream to the appliance The blue air vent cap on the top of the regulator is pa...

Page 7: ...lockwise then light standing pilot and adjust flame 1 4 high 6 Turn ON gas valve thermostat to light main burners 7 For complete shut down shut off gas valves and turn pilot adjustment screw clockwise...

Page 8: ...urner on very low and allow oil to burn off Repeat the procedure three times before regular use 2 Remove and empty grease pan Clean thoroughly and replace 3 Remove rack and grease pans Clean with soap...

Page 9: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5...

Page 10: ...Manual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 ARMG O N OFF O N OFF O N OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 11: ...nifold ARHP 72 ARMG 72 6HT 1801 72 Counter Top 5 A29300 Valve Pilot Elbow Adjustable 10418 1 8 NPT 3 16 CC 6 A23010 Plug 1 8 Pipe Hex Black All Manifolds 7 A29201 Pilot Tip Assembly ARMG 8 A29000 Hood...

Page 12: ...er s Manual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 8 ARTG 20 19 18 16 11 8 2 1 21 3 4 5 6 7 9 10 13 12 14 15...

Page 13: ...0 Heavy Duty 1902 60 Stainless A80122 Valve Cover ARTG 72 Heavy Duty 1902 72 Stainless 9 A32020 Knob Griddle BJ Thermostat 10483 10 A32012 Bezel BJ Thermostat 10440 11 A11113 Thermostat BJ Griddle Gas...

Page 14: ...nual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 AEMG 1 O N OFF O N 2 6 3 4 5 7 8 9 10 11 12 13 16 18 19 20 21...

Page 15: ...A44003 Nut Speed 6 Push Black 10601 9 A38000 Name Plate American Range 8 10499 Quality Commercial Chrome 10 A32140 Bracket Handle AEMG Rt Heavy Duty Chrome Plated 1 Tube 11 A53053 Tube Handle AEMG 12...

Page 16: ...Manual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 AETG 24 22 20 21 23 19 18 13 15 16 17 4 1 10 5 4 9 8 6 2 3...

Page 17: ...Owner s Manual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 13 AETG need parts...

Page 18: ...Owner s Manual ARMG ARTG AEMG AETG ACCG ARGB ARTY 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 14 ARTY 1 2 3 4 8 6 7 10 11 12 13 5 14 15 9...

Page 19: ...4 10480 LP Gas Set 5 A80011 Valve Pressure Regulator 3 4 10481 LP Gas Set 10 0 5 A29220 Pilot Assembly ARTY Series 6 A29300 Valve Pilot Elbow Adjustable 10418 1 8 NPT 3 16 CC 7 A32001 Knob Gas On Off...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: