StorTrends® 3100 User’s Guide
28
Serial ATA Back Panel
SATA Jumpers
Default
Setting
More Information
A JP18
Open
Buzzer
Reset
B
JP25
1-2
Overheat Temperature#1 50 degrees Celsius
C
JP45
1-2
Overheat Temperature#2 50 degrees Celsius
D
JP26
Open
Common Activity In and Activity #0-#7 In
E
JP47
Open
Common Activity In and Activity #8-#14 In
F
JP61
Closed
Fan #1 Enabled
G
JP62
Closed
Fan #2 Enabled
H
JP63
Closed
Fan #3 Enabled
I
JP64
Closed
Fan #4 Enabled
Note:
Press the button on the front panel once to disable the buzzer. If the buzzer has been
disabled, press the button again to re-enable the buzzer.
Jumper Settings Location
A
C
F
B
G
H
E
D
I
Fan#1
Fan#2
Fan#3
Fan#4
Note:
By default, we connect four chassis fans to the drive backpanel.
Note:
When connecting the 760W Power Supply to the Drive Backplane, be sure to connect the
power supply to the connectors labeled "PD", "PE" and "PH" (with yellow/green stripes),
and then, to the connector labeled "PJ", colored in yellow/blue stripes.