Appendix B Audible Warnings
89
B Audible Warnings
The MegaRAID Express 500 RAID controller has an onboard tone generator
that indicates events and errors.
Tone Pattern
Meaning
Examples
Three seconds on
and one second
off
A logical drive is
offline.
One or more drives in a RAID
0 configuration failed.
Two or more drives in a RAID
1, 3, or 5 configuration failed.
One second on
and one second
off
A logical drive is
running in degraded
mode.
One drive in a RAID 3 or 5
configuration failed.
One second on
and three seconds
off
An automatically
initiated rebuild has
been completed.
While you were away from the
system, a disk drive in a RAID
1, 3, or 5 configuration failed
and was rebuilt.
Important
The audible warning were not enabled at the time this manual
went to press.