1-14
American-Lincoln
3366XP
HYDRAULIC FLUID SIGHT GLASS See Figure 3
The sight glass is located on the side of the hydraulic oil reservoir.
The sight glass indicates the level of the hydraulic oil in the reservoir.
Fluid level must be visible in the sight glass when the hopper is in the down position. If the sight glass is
completely full, then there is too much fluid in the reservoir.
BROOM & FAN SWITCH See Figure 2
The broom and fan switch is located to the left of the right side broom lever. This switch “powers” the
brooms and the vacuum fan system. It has on-off positioning.
SHAKER MOTOR SWITCH See Figure 2
The shaker motor switch is located below the broom and fan switch. This is a momentary switch that will
activate the filter shaker motors. Hold the switch for 20 to 30 seconds to activate the shaker motors. When
the shaker motors have been activated, the brooms and impeller fan will stop. The shaker motors will only
operate with the hopper in the “SWEEP” position. The switch is not on the control panel if the machine is
equipped with the CDC Dust Control Filter Option.
TIMED SHAKER MOTOR SWITCH (OPTION) See Figure 2
The shaker motor switch is located below the broom and fan switch. This is a momentary switch that will
activate the filter shaker motors for 20 to 30 seconds after it has been pushed. When the shaker motors
have been activated, the brooms and impeller fan will stop. The shaker motors will only operate with the
hopper in the “SWEEP” position.
OPERATION OF CONTROLS AND GAUGES
HYDRAULIC
SIGHT GLASS
P4696a
FIGURE
3