CONTROLLER OVERVIEW 

NOTE:  The following controllers are compatible with the single color IP65 tape light. Alternatively, use the Trulux application with one or 

more WIFI receivers (REC-5A-4Z-WIFI); one receiver is needed for each zone. 
Visit www.americanlighting.com/truluxapp.html for a direct access link or visit the App Store or Google play marketplace to download the 

Trulux application. 

1.    Determine which controller is best suited for your application. See list below. 

2.  Select a receiver for each zone. For RF controllers, use one REC-5A-4Z for each zone. For the Trulux app, use one REC-5A-4Z-WIFI for each 

zone. For WIFI setups with 2-8 zones, you will need a WIFI hub (WIFI-RF-8, sold separately). You can use a REC-5A-4Z-WIFI in conjunction with 

wall mount and/or handheld controllers; in addition to using the App.  

  

CONTROLLER 

POWER TO CONTROL 

RECEIVER ITEM # 

CAPACITY 

   POWER TO RECEIVER

 

SRF-BATT (White, dial) 

3V Battery (CR203, included) 

REC-5A-4Z 

1 zones, 5A max 

24V DC input 

 SRF-4Z-3P (White, touch) 

24V DC input (not 120V!) 

REC-5A-4Z 

4 zones, 5A max 

24V DC input 

See Figure 3 for an example of a multiple zone system. However, note that you can have receivers “learn” which zone they control, so if 

you teach them all to respond to one zone, then Figure 3 represents a single zone system that has multiple runs of Trulux.

Page 3 of 4

11775 E. 45th Ave. Denver, CO 80239   Ph: 1-800-880-1180   Fax: 303-695-7633

©2017 American Lighting, Inc.   REV1743  www.AmericanLighting.com

FIGURE 5

Supply the receiver 

with 12V DC power, 

matching polarity: 

red = (+) and black = (-)

SR-1009FA

LED CONTROLLER

Learning

 

Key

ww re

d 1

cw

gr

een 2

ww blue 3

cw whit

e

4

Receiver requires 

12V input

Connect lead wires from tape light 

to receiver, matching polarity: 

red = (+) and black = (-)

RECEIVER

TAPE LIGHT LAYOUT EXAMPLES USING L, T AND X CONNECTORS

                                AWM 2468     22AWG     80°C     300V     AWM     cRI     AWM 2468     22AWG     8

0°C     300V     AWM     cRI      

TRULUX

®

 HIGH OUTPUT MAX

24V

INSTALLATION INSTRUCTIONS

HTMR Series

Summary of Contents for TRULUX HIGH OUTPUT MAX Series

Page 1: ...onal Electric Code NEC Use only with 24V DC drivers with a wattage capacity that can handle the total load see page 2 for more details Factory warranty will be void if used with a non recommended power supply transformer or driver To reduce the risk of fire electric shock or injury to persons make sure that the electrical power to the system is disconnected at the source prior to installation or a...

Page 2: ...ece connect a clip connector or jumper wire to the preceding piece by sliding the tape light end completely into the connector ensuring the tape light is underneath the metal conductors and closing the clip securely over the tape light until the connector halves snap together See Figure 2 Compatible clip connectors include TL 2SPL TL 2L TL 2T and TL 2X Jumpers TL 2JUMP 5 TL 2JUMP 1 and TL 2JUMP 2 ...

Page 3: ...EM CAPACITY POWER TO RECEIVER SRF BATT White dial 3V Battery CR203 included REC 5A 4Z 1 zones 5A max 24V DC input SRF 4Z 3P White touch 24V DC input not 120V REC 5A 4Z 4 zones 5A max 24V DC input See Figure 3 for an example of a multiple zone system However note that you can have receivers learn which zone they control so if you teach them all to respond to one zone then Figure 3 represents a sing...

Page 4: ...USING PLUG IN POWER SUPPLY FOR TRULUX NON DIMMING 1 See plug in driver selection chart below 2 Attach the DC power lead adapter not included with 100ft reels to the existing lead matching polarity Attach DC jack from this power cord to DC jack of plug in power supply sold separately Plug power supply into 120V AC power source ADDITIONAL SAFETY MEASURES 1 Route and secure cords so that they will no...

Reviews: