Page 3

State of Massachusetts: The installation must be made by 

a licensed plumber or gas fitter in the Commonwealth of 

Massachusetts.

Sellers of unvented propane or natural gas-fired supplemen

-

tal room heaters shall provide to each purchaser a copy of 

527 cMr 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural 

gas-fired space heaters shall be prohibited in bedrooms and 

bathrooms.

Proper Log Placement

Log placement is critical to proper burner performance. Logs must 

be correctly positioned onto the burner. The photos in this manual 

show the proper pinned position for logs on this set. Owners need 

to be shown proper log placement and instructed not to move the 

logs. 

Logs must fit firmly onto the burner when positioned as shown in 

the photos. Malformed logs or logs with sloppy pin holes must be 

replaced.

Proper Placement of rock wool and Decorative Lava rock

Rock wool can be added to burners for a glowing ember effect. 

It must be positioned only on the front portion of the burner. The 

photos in this manual  show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed 

on the burner. These items are only for placement on the floor of 

the fireplace or firebox.

Proper Primary Airflow into Burner

For  proper  burner  operation  and  flame  appearance,  the  flow  of 

primary air into the venturi tube, located on the rear of the burner, 

must not be reduced. This flow of air is reduced if dirt, lint or other 

obstructions build-up around or inside the venturi. Any obstruction 

in the venturi tube area must be removed. The flow of air into the 

venturi is also reduced if the gas orifice isn’t centered in the venturi 

inlet and/or is not aligned with the venturi. Any misalignment of the 

burner orifice may be corrected by bending the shutter cap holding 

the orifice to the inlet of the venturi tube.

ceiling fans, Portable fans or Logs Installed Near cold Air 

returns

Ceiling fans or oscillating floor type fans need to be monitored 

during the operation of vent-free logs. If the air blows directly 

into the flame causing it to impinge on the log set, or firebox, it 

should be turned off or redirected. Ceiling fans could be reversed 

to possibly eliminate flame impingement, and the floor fan could 

be redirected. Upon installation, be aware of any cold air returns 

or vents in the proximity of the log set. Any draft created around 

a vent-free log set can cause the flame to impinge on the log and 

create a sooting situation.

wArNINg: 

Do not allow fans to blow directly into the fireplace. 

Avoid any drafts that alter burner flame patterns.

wArNINg: 

Do not use a blower insert, heat exchanger insert or 

other accessory not approved for use with this heater.

candles

Avoid the use of scented or decorative candles while the log set is in 

operation. Candles produce a residue in the air that creates a soot like 

substance. Burning candles while the log set is operating magnifies 

the problem. It should be noted that candles, in general, produce 

soot. The amount of time burned and the quantity of candles burned 

will determine the amount of soot produced and deposited.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit 

soot on the logs. If users see soot appear on a log, call for service. 

Do not continue to operate the log set.

Sunken fireplace

If installing this unit into a sunken fireplace, you must raise the 

floor to insure adequate airflow and guard against sooting. Raise 

fireplace floor using a non-combustible material, which is secure.

glass Doors

Make sure that glass doors are open during all operations of the log 

set. The opening of the glass door frame should be the dimension 

used for the minimum front opening of the firebox.

woodburning fireplaces

The interior of the firebox and the chimney should be cleaned and 

free of all creosote before installing a gas burning log set. Creosote 

will soften when heated and can drop on the log set causing odors 

and possibly sooting.

wArNINg: 

Before installing in a solid-fuel burning fireplace, the 

chimney flue and firebox must be cleaned of soot, creosote, ashes 

and loose paint by a qualified chimney cleaner.

IMPOrTANT INSTALLATION guIDeLINeS

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip

-

ment or accessories and repair and servicing of equipment shall be 

performed only by a qualified agency. The term "qualified agency" 

means any individual, firm, corporation, or company that either in 

person or through a representative is engaged in and is responsible 

for (a) the installation, testing, or replacement of gas piping or (b) the 

connection, installation, testing, repair, or servicing of equipment; 

that is experienced in such work; that is familiar with all precau

-

tions required, and that has complied with all the requirements of 

the authority having jurisdiction.

The installation must conform with local codes or, in the absence 

of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/

NFPA54

.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St., 
New York, N.Y. 10018.

geNerAL INfOrMATION

Summary of Contents for MONTICELLO ALS-18MN-1

Page 1: ...ocal codes WARNINGS Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do n...

Page 2: ...3 Requirements for Canada 4 Monticello Log Placement 5 Ember Placement ALS 18MN 1 Photos 6 Ember Placement ALS 24MN 1 Photos 7 Ember Placement ALS 30MN 1 Photos 8 Parts List and Parts View 9 Master P...

Page 3: ...the log and create a sooting situation WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns WARNING Do not use a blower insert heat exchanger...

Page 4: ...an those supplied for use with the log set 6 Also refer to IMPORTANT SAFETY INFORMATION on page 3 of this manual WARNING DO NOT OPERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED Clothing or other flamm...

Page 5: ...e burner 3 Place Left Front Log A on front left two pins on the burner 4 Place Rear Log D on the two pins on the the rear log support 5 Place Left Top Log F on the left pin of the D log and the pin on...

Page 6: ...Page 6 EMBER PLACEMENT ALS 18MN 1 PHOTOS Photo 1 Photo 2 Photo 3 Photo 4 Do not cover any large rear ports with loose material glowing embers Do not cover any large front ports with loose material gl...

Page 7: ...Page 7 EMBER PLACEMENT ALS 24MN 1 PHOTOS Photo 1 Photo 2 Photo 3 Photo 4 Do not cover any large rear ports with loose material glowing embers Do not cover any large front ports with loose material gl...

Page 8: ...Page 8 EMBER PLACEMENT ALS 30MN 1 PHOTOS Photo 1 Photo 2 Photo 3 Photo 4 Do not cover any large rear ports with loose material glowing embers Do not cover any large front ports with loose material gl...

Page 9: ...D F INDEX NO PART NO DESCRIPTION ALS 18MN 1 A R10212 LEFT FRONT LOG B R10213 RIGHT FRONT LOG C R10214 MIDDLE LOG D R10216 REAR LOG E R10215 REAR TOP LOG F R10217 LEFT TOP LOG ALS 24MN 1 A R10219 LEFT...

Page 10: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Page 11: ...24976 1 0210 Page 11 SERVICE NOTES...

Page 12: ...Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question pl...

Reviews: