![american flame AF-LMF-RV Installation And Operating Instruction Download Page 5](http://html1.mh-extra.com/html/american-flame/af-lmf-rv/af-lmf-rv_installation-and-operating-instruction_2924469005.webp)
REV. 11-30-18 Page 5
American Flame: AF-LMF Series Valve Kits
Burner Pan
4.00”
Fig. 8
Shows approximate pilot location from end of
burner pan.
NOTE: VALVE BOX MUST BE LOCATED A MINIMUM OF 2-INCHES FROM SIDE OF THE
BASKET GRATE AND NEVER PLACED DIRECTLY IN FRONT OR BEHIND THE BASKET GRATE
Fig. 10
Shows clearances to be maintained inside fire box.
Optional Valve
Mounting Location
Valve Box Kit
2.0” Min.
2.0” Min
.
2.0” Min.
2.0” Min.
Burner Pan
Basket Grate
4.0”
4.0”
Optional Pilot
Mounting
Pilot Mounting
Burner Pan
Pilot Assembly
Fig. 9
Show side view of pilot assembly mounted on
edge of burner pan 4-inche from end.