For mounting the unit flush to a wall or other rigid 
surface, the ears may be installed on the sides 
with the oval holes flush with the bottom of the unit 
as in Figure 2. Mount the ears with the #10 
flathead screws provided. Mount the  
unit to a rigid surface using #10 (5mm) screws. 
 

POWER SOURCE 

The internal power supply accepts universal line voltage. Any mains supply from 100 to 
240 VAC, 50 to 60 Hz, may be used without modification or adjustment. A universal 
power connector is provided on the rear of the unit to facilitate connection to the power 
mains.  

 
POWER CONNECTION 

The unit is supplied (in the US and UK only) with a three conductor power cord. The 
“ground” conductor is directly connected to the chassis.  

INPUT / OUTPUT CONNECTIONS 

The fiber optic connection is made via a FC/PC connector located at the back of the unit. 
Be sure to allow sufficient room for the required minimum bend radius of the fiber cable 
used. 
 
Video input and output connections are located on the rear of the unit. A BNC connector 
is provided for each channel. The video inputs are connected to an appropriate 75

 

baseband video source such as a camera or a video recorder output. The 75

 video 

outputs can be looped through typical baseband video inputs of switchers, recorders and 
other equipment as required. For proper operation, the outputs must be terminated with 
75

. For optimum performance the video cables should be the shortest length of coax 

practical. 
 
Data input and output connections are located on the rear panel terminal block. A mating 
plug connector is provided.

 

The figure below identifies the specific connections for the 

Sensornet data connections. 
 

 

Summary of Contents for MTX-8410C-SL

Page 1: ...Copyright 2005 American Fibertek Inc 1213JD Instruction Manual MTX 8410C SL MRX 8410C SL Four Channel Video Multiplexer with Bi directional Sensornet Data...

Page 2: ...tional Description 3 Installation 3 Power Source 4 Power Connection 4 Input Output Connections 4 Data Configuration 5 MTX 8410C SL Status LED Indicators 6 MRX 8410C SL Status LED Indicators 7 Warranty...

Page 3: ...pondingly the MRX 8410C SL receiver converts the optical signal to four independent video output signals along with the data signals The 8410C SL Series units operate on 9 um singlemode fiber Refer to...

Page 4: ...PUT CONNECTIONS The fiber optic connection is made via a FC PC connector located at the back of the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used V...

Page 5: ...of switch 5 these switches must remain in the positions shown below to properly transmit Sensornet data Switch 5 is used to apply a 120 termination resistor across the data I O connections These units...

Page 6: ...t panel DATA LEDs are listed below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Sensornet Tx Sensornet Rx Tx Carrier Detect Rx Carrier Detect OLI A bi color LED indicator monitors the optical input power o...

Page 7: ...typically appear dimmer than the Sensornet Tx and Rx LEDs The data activity associated with these front panel DATA LEDs are listed below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Sensornet Tx Sensornet...

Page 8: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...

Reviews: