American Dynamics SpeedDome RASEL Series Installation And Service Manual Download Page 1

 

SPEEDDOME OPTIMA LT INDOOR CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0181-01, REV. C) 

1 of 14 

!

SpeedDome

®

  

Optima LT Indoor 
Camera Dome 

RASEL Series 

Installation and Service Guide 

 

 

The SpeedDome Optima LT indoor camera dome 
mounts either to a hard ceiling or to a 2x2 tile 
ceiling using a mounting plate (instructions for the 
plate are supplied separately). 

CAUTION:

 Save the box and packing 

materials. These materials are required 
should you need to ship the dome to a 
repair center. 

Note:

 The dome accepts either cable or conduit. If 

running cable through a plenum ceiling, either 
plenum-rated cable or flexible conduit is required.  

 

© Sensormatic 2003 

Contents 

Warnings ............................................................2

 

Before You Begin ...............................................3

 

Installation ..........................................................6

 

Troubleshooting .................................................9

 

Parts List for Authorized Users ........................10

 

Specifications ...................................................12

 

Declarations .....................................................14

 

 

Customer Support 

If you need assistance, contact your sales 
representative. 

Summary of Contents for SpeedDome RASEL Series

Page 1: ...te are supplied separately CAUTION Save the box and packing materials These materials are required should you need to ship the dome to a repair center Note The dome accepts either cable or conduit If running cable through a plenum ceiling either plenum rated cable or flexible conduit is required Sensormatic 2003 Contents Warnings 2 Before You Begin 3 Installation 6 Troubleshooting 9 Parts List for...

Page 2: ...tended to be powered from a Limited Power Source A limited power source is a certified source of SELV and if inherently limited with 8 amps maximum output current and a maximum of 100VA available or if not inherently limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through Sensormatic or through another ...

Page 3: ... 18 AWG Connection Non polarized Polarized Max devices per cable run 32 3 Power data and video cables can be ordered separately or within a composite cable that can be ordered in various lengths Plenum rated cables must be used in indoor ceilings used for environmental air return called other air space in the National Electrical Code Order parts through your distribution network Note If you order ...

Page 4: ... video and dome control signals The adapter does not require power One adapter is supplied If used another adapter must be ordered to for the connection at the other end of the cable The figure below shows twisted pair cable connections See installation guide 8200 0298 01 for details Indoor Dome Worst Case Meters AC Power Source Low Line V Feet 28 VA 117 130 425 Transformer 100 80 250 5604 0006 01...

Page 5: ...for address 107 set SW3 to 1 SW2 to 0 black dot and SW1 to 7 Compatibility with the VM96 Controller If using a VM96 controller the controller must be Version 5 2 or higher Power Up Routine After power is connected to the dome the dome performs a homing routine During the homing process the camera will pan and then either Go to the start point of the apple peel pattern or If powered up once before ...

Page 6: ...P10 4 Set address switches SW1 SW2 and SW3 for the address for example 001 016 for VM16 001 096 for VM96 5 If daisy chaining domes the dome furthest from the video controller requires that termina tion switch S1 remain in the terminated position resistor symbol All other domes along the chain must be set to un terminated 6 Inside the opening check communications DIP switch S2 for the correct setti...

Page 7: ...s into their mating connectors in the top of the dome housing WARNING Ensure power is off at the source when connecting cables Otherwise the dome will operate during installation 14 Reattach the cover plate to the dome housing 15 Using safety wire attach the dome to a strong structural ceiling member as follows a Find a strong structural member capable of supporting the dome Wrap one end of the wi...

Page 8: ...the last position in memory Once the camera stops the camera is online and is ready to be controlled Also green red and yellow LEDs will light in various patterns to indicate status Typically you do not need to view these LEDs unless a failure occurs during or after the routine See Troubleshooting for an explanation of the LED patterns 19 Once the homing routine completes affix the bubble to the d...

Page 9: ...ill cause the LED to blink otherwise the LED is off No video 1 Check the video cable and its connection to the dome If not OK fix or replace the cable 2 Check the iris setting Open iris or set to auto iris 3 If the problem cannot be corrected send the dome to a repair center Video rolls when switching cameras Perform V phase adjustment at the controller Contrast or color off 1 Check the iris setti...

Page 10: ...bble Assembly Clear 0100 2458 01 6 Bubble Assembly Smoked 0100 2458 02 Tilt Assy 0400 1207 01 NTSC 02 PAL 7 Base Tilt 0500 9110 01 8 Gear Camera Base 0500 9112 01 9 Tilt Upright 2 0500 9168 01 10 Camera Hitachi VK S144 NTSC 2003 0037 11 11 Camera Hitachi VK S144 PAL 2003 0037 12 12 Timing Belt 2500 0041 01 13 Tilt Motor with Pully 3501 0024 01 14 PCB Tilt Sensor 0301 1524 01 15 Ribbon Cable 20mm B...

Page 11: ...SPEEDDOME OPTIMA LT INDOOR CAMERA DOME INSTALLATION AND SERVICE GUIDE 8200 0181 01 REV C 11 of 14 8 12 9 17 16 19 20 Tilt Assy 0400 1207 01 02 Base Assy 0404 0008 01 18 7 13 14 15 10 11 ...

Page 12: ... Interline Transfer CCD array Scanning system 2 1 interlace Horizontal resolution 450 lines at center Video out 1 0 Vp p 75 ohms composite Signal Noise 50dB typical Minimum illumination 1 0 lux 20 IRE Gain control Automatic AGC White balance Through the Lens TTL Automatic Tracing White Balance ATW NTSC version Pickup device 768 H x 494 V pixels Scanning 525 lines 60 fields 30 frames Horizontal 15 ...

Page 13: ...tube impulse rated at 8 20µs impulse discharge current 10kA Ten 8 20µs impulses discharge current 5kA Isolation transformer coupled 2000Vrms PTC resettable fuse protects transformer TVS rated at 5 6V 40A 0 1 Joules 8 20µs impulse SensorNet Communications Address range 0 to 255 Bit rate 230 4Kbps Network distance 1km Maximum loads 32 per node Node repeaters SensorNet junction boxes Cable topologies...

Page 14: ...ealers The dealer through whom you originally purchased this product is your point of contact if you have a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation make...

Reviews: