51
Installation Manual
connection via an Ethernet hub or switch. Alternatively, a PC can be connected directly to a RS232 port on the primary
matrix, but it is preferable to use an Ethernet connection when running the Easy 48 configuration software.
See page 30 for more details on connecting a PC to a MegaPower 48+.
Manchester, SensorNet and SEC-RS422 Connections in a Multi-Matrix System
In a multi-matrix system, telemetry connections via Manchester, SensorNet or SEC-RS422 protocols are made in the
same way they would be in a single matrix system. See page 16 for more details.
The only restriction in a multi-matrix system is that connection of the SensorNet, Manchester or RS422 must be made
to the same matrix that the camera video input is connected to. The receiver or dome should be addressed as the port
number on that unit. For example If camera 49 is connected to secondary matrix B, then the control connection must
also be made to matrix B and the address would be “1” as the camera is connected to port 1 on matrix B.
A quick look-up table for Mode 1, 2, and 3 configurations is provided on page 53.
Alarm Connections in a Multi-Matrix System
Each connected matrix can have 16 patch panel alarms, four dome camera alarm inputs per connected AD dome
(SensorNet or SEC-RS422 only) and 48 video loss alarms. A maximum of 512 RS232 alarms, wired through AD2096A
Alarm Interface units, can be included in a system (see
RS232 Connections
above).
Each connected matrix can also have two relay outputs. When configuring the system using the software embedded in
the system’s Main Electronics Unit or with the Easy 48 configuration software, it is possible to specify that any relay
output on any matrix can be energized when an individual alarm input is triggered.
See page 35 for more details on connecting individual alarms.
MegaPower 48+ System Troubleshooting
MegaPower 48+ System Troubleshooting
Declaration of Conformity
Manufacturer:
Sensormatic Video Systems Division
Sensormatic Video Systems Division
1 Blue Hill Plaza
6795 Flanders Drive
Pearl River, NY 10965 USA
San Diego, CA 92121
Sensormatic Electronics Corporation
State Rd. 110 Km 5.8
Poblado, San Antonio
Aguadilla, P.R. 00690
Declares, that the product(s) listed below:
Equipment Type:
Matrix Switcher/Controller System
Product Name:
MegaPower 48+
Model Number:
VR48*
* Depending on system configuration the model number indicated above will be modified by additional coding.
Complies with the standards:
EN55022 (Class B) Emissions
EN50130-4
Immunity
EN60950
Safety
Additional Information:
These products herein, comply with the requirements of the EMC Directive 89/336/EEC, and with the Low Voltage
Summary of Contents for MegaPower 48 Plus
Page 1: ...MegaPowerTM 48 Installation Manual ...
Page 7: ...7 Installation Manual Drawing 1 MegaPower 48 Mechanical Installation Wall Bracket Assembly ...
Page 10: ...10 MegaPowerTM 48 Drawing 4 AC Power Section Patch Panel to Transformer Cable ...
Page 13: ...13 Installation Manual Drawing 6 MegaPower 48 Patch Panel ...
Page 15: ...15 Installation Manual Drawing 7 Patch Panel to Video Inputs and Video Outputs ...
Page 25: ...25 Installation Manual Drawing 14 RS232 Communications Patch Panel to ADCC1100 Keyboard ...
Page 28: ...28 MegaPowerTM 48 Drawing 17 RS232 Communications Patch Panel to ADTTE Keyboard ...
Page 31: ...31 Installation Manual Drawing 19 RS232 Communications Connections to PC and External Modem ...
Page 34: ...34 MegaPowerTM 48 Drawing 22 Ethernet Connections to a PC ...
Page 36: ...36 MegaPowerTM 48 Drawing 23 Patch Panel Alarms and Relay Sections ...
Page 54: ...54 MegaPowerTM 48 Control Addressing Quick Look Up Table ...
Page 56: ...56 MegaPowerTM 48 ...
Page 61: ...61 Installation Manual ...
Page 62: ...62 MegaPowerTM 48 ...
Page 63: ...63 Installation Manual ...