background image

Installation Instructions

8000-2671-02, Rev. A (7 pages)

AMERICAN DYNAMICS PRODUCTS

1

1

 

AD32 Enhanced T

OUCH

T

RACKER

®

1

 ADTT32E

With Video Matrix Switcher

A

B

C

D

1

2

3

4

5

6

7

8

9

0

Peel

Info

On

Outp

ut

Off

Clea

r

Men

u

Iris

Clos

e

Open

Flip

View

Patte

rn

Repe

at

Patte

rn

Seq

Previo

us

Next

About this Guide

This installation guide explains the procedures for
installing Enhanced T

OUCH

 T

RACKER

 controllers

with the Video Matrix Switcher. Other related
documents are:

  Installation and Service Manual, 8000-1702-02

  Operator's Manual, 8000-2655-02

Note:

 Because customer requirements dictate the

placement of T

OUCH 

T

RACKER

 components, your

Sensormatic representative will supply this
information separately.

If you need assistance...

Call Sensormatic Customer Support at:

1-800-543-9740

                                                     

1

T

OUCH 

T

RACKER

, Sensormatic

, and the 

Sensormatic logo

 are

registered trademarks of Sensormatic Electronics Corporation. Other
product names (if any) mentioned herein may be trademarks or
registered trademarks of Sensormatic or other companies.

No part of this document may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
© Copyright 1999. All rights reserved.
(CSD) 07/99

Parts Required

T

OUCH

 T

RACKER

 Installation Kit:

Part Number 0351-0474-07

INSTL KIT, TOUCH TRKR, W/RJ45

1

Description

Qty Part No.

CABLE ASSY,MDLR,14FT,8 COND,CROSS-P

1

6003-0047-01

SCR,THD CUT,M2.9X9.5,PHP,ST,Z,T1

1

5899-0004-102

ANCHOR,PLASTIC,W/O SCREW,8-10

2

2880-0083-01

SCR,TYP AB,PHP,CAD,#8X1"

2

2816-7634-44

CONN,PLUG,TUBLR,.200CTR,26-12AWG,1X

1

2109-0254-04

LUG,SPADE,CRIMP,INSUL,22-16AWG

3

2141-0002

CABLE,3COND,18AWG,CM

16.5

6002-0024-01

INTERCONNECT BOX,TOUCHTRACKER

1

0300-1000-01

CABLE ASSY,TOUCH TRACKER,INTFC TO Q

1

0650-0932-01

HOOD,D-SUB,9POS,EMI/RFI,.25 DIA CAB

1

2125-0007-02

CONN,D-SUB,PLUG,HSG,9POS,SSI

1

2130-0021-01

FERRITE CORE

1

2700-0023-01

QUICK REFERENCE GUID

1

8000-2656-02

TOUCH TRACHER STRAIN RELIEF INSTR

1

8000-1370-01

WARNING Shock Hazard!

Disconnect AC Power.

CAUTION static sensitive

components!

Follow proper handling procedures to
prevent component failure.

Installation Procedures

See 

Remote Switcher Location

 for procedures

when the Video Matrix Switcher will be more than 4m
(14 ft) from the EIMs.

1.  Attach each EIM to a wall or other surface within

3m (10 ft) of its 

T

OUCH

 T

RACKER

 controller.

2.  Terminate the EIM that is at the end of the

SensorNet network.

 

See 

Figure 1

 for the wiring diagram for a typical

2-controller AD32 system installation. For more
information on the SensorNet network, see the

SensorNet Network Guide

 (PN 8000-0970-01).

3.  Attach the 3 spade lugs to one end of the 3-

conductor cable, then attach the lugs to the EIM
power transformer.

Summary of Contents for ADTT32E

Page 1: ...mber 0351 0474 07 INSTL KIT TOUCH TRKR W RJ45 1 Description Qty Part No CABLE ASSY MDLR 14FT 8 COND CROSS P 1 6003 0047 01 SCR THD CUT M2 9X9 5 PHP ST Z T1 1 5899 0004 102 ANCHOR PLASTIC W O SCREW 8 1...

Page 2: ...ary TOUCH TRACKER Secondary TOUCH TRACKER Video Matrix Switcher EIM DB9 M COLOR PIN FUNCTION Green 3 Receive Red 2 Transmit Orange 5 Ground NOTE View Manager 32 supports up to 2 controllers Terminate...

Page 3: ...oot to the Camera Control Mode Figure 2 Ferrite Core Attachment 0 in 2 54 3 81 cm 1 1 5 Resetting a Dome 1 Use the number buttons to select the dome to reset then press the Camera button 2 Press Menu...

Page 4: ...the number buttons to select a dome to test then press the Camera button 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the zoom top line or focus bottom line button to sel...

Page 5: ...s to one end of the 3 conductor cable then attach the lugs to the EIM power transformer 6 Connect the power transformer cable and the SensorNet data cable and if required the data cable to EIM 2 to th...

Page 6: ...2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 1 2 3 4 5 6 7 8 SI NO NC C 1 2 3 4 5 1 2 3 RS232 PORTS MONITORS ALARMS RELAY 120V 60Hz CAMERAS Transforme J3 Wiring Pin Function 1 N A 2 24Vac A 3 Ground 4...

Page 7: ...on 1 Ground 2 Alarm 1 3 Alarm 2 4 Alarm 3 5 Alarm 4 6 Alarm 5 7 Alarm 6 8 Alarm 7 9 Alarm 8 10 Ground 11 External Sync Ground 12 External Sync Input 13 Ground 14 Relay Normally Open 15 Relay Normally...

Reviews: