Troubleshooting 

This section covers what to do when: 

  Dome does not respond to commands 

  Fans do not turn 

  Picture is grainy or discolored 

 Poor 

video 

  Ice forms on bubble. 

CAUTION:

 Some steps in this section 

involve tightening wire connections.  

-  Use a 2.5mm (0.1in) slotted 

screwdriver. Using a blade too wide 
can damage connectors. 

-  Screws on the ac connector are 

delicate. DO NOT over tighten them! 

Dome Does Not Respond to Commands 

Follow steps until the problem is corrected. See 
page 5 to order parts. 

1.  Detach the camera dome from the base and 

check the address switches. Are they set 
correctly? 
- YES: 

Continue. 

-  NO: Set the correct address and reconnect 

the dome. 

2.  Verify power is reaching the housing. Press and 

hold switch SW2 on the environmental PC 
board and observe the green (ac power) LED. 
Does the LED glow steadily? 
-  YES: Reattach the dome and continue. 
-  NO: Check power at the J-box and ac cable 

connections at connector P7 on the other 
side of the environmental PC board. If OK, 
replace the PC board. 

Connector P7 pin outs 

Pin Color  Description 
1 N/A  24Vac 
2 N/A  Common 
3 N/A  24Vac 

3.  Verify data is reaching the housing. 

SENSORNET or RS-422: Press and hold switch 
SW2 on the environmental PC board and 
observe the yellow (comm.) LED. The LED 
should blink (SensorNet) or glow steadily 
(RS-422). 
To verify RS-422 connections at connector P1, 
press and hold data test switch SW1 on 
environmental PC board. Check the nearby red 
and green LEDs; they indicate the following: 

Constant green, 
Blinking red 

RS-422 line is correctly 
wired. 

Constant green, 
No red 

RS-422 “Data In –” is 
shorted to ground. 

Constant red, 
Blinking green 

“Data In + /–” wires are 
reversed. 

Blinking red, 
Green off 

“Data In +” is shorted to 
ground. 

Both LEDs off 

“Data In +/–” wires are 
shorted or open. 

P1 pin outs: 

Manchester data connections (Ultra IV only) 

Pin Color 

Designation 

1-4 — 

Not 

used. 

5 White/Orange 

Manchester 

(White) 

6 White/Yellow 

Manchester 

(Black) 

 

RS-422 Data connections 

Pin Color  Designation 

Orange 

RS-422 Data In High (+) 

Green 

RS-422 Data In Low (–) 

Yellow 

RS-422 Data Out High (+) 

Brown 

RS-422 Data Out Low (–) 

5-6 — 

Not 

used. 

Summary of Contents for ADSDUHOC

Page 1: ...installation site To install the outdoor mounting structure see documents shipped with the structure About the Product The outdoor housing has a sunshield cover and bubble that protect the SpeedDome Ultra dome camera Tamperproof screws affix the bubble to the housing The housing is temperature controlled and weatherproof A built in thermostat and heater prevent ice from forming on the outside of t...

Page 2: ... limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through American Dynamics or through another source where the provider can furnish the required certification This is required to assure electrical safety in the product Cautions Water leaks even small ones can increase humidity inside the outdoor housing...

Page 3: ...sket seal between the bubble and the housing Ensure lanyard is not caught between a flange and trim ring gasket and b trim ring and sunshield In high humidity environments the desiccant bag may need to be replaced occasionally Parts List for Authorized Users The parts listed below and shown in the exploded view can only be ordered by authorized users To become authorized contact your sales represe...

Page 4: ... SensorNet RS 422 and Manchester networks For more information about communication protocols and cable networks see Communication Protocols and Cable Networks 8000 2573 19 Data cable requirements SensorNet RS 422 Manchester Cable type 1 unshielded twisted pair 2 shielded twisted pair 1 shielded twisted pair Wire gauge 22 AWG 22 AWG 18 AWG Connection Non polarized Polarized Polarized Max devices on...

Page 5: ...ng finger connector Note Keep the dust cover in place for the next two steps On the circuit board 1 Set the termination jumper E1 according to the dome s position in the communications line Position of dome in communications line Setting Pins Between other devices Unterminated Off End of communications line Terminated 1 2 Note You may need a small slotted screwdriver to gently pry the jumper loose...

Page 6: ... circuit board is a mark shown below To reattach the board to the housing match the mark to an identical mark on the base and snap the board in place 4 Gently remove the dust cover Note Keep the cover and use it to protect contacts should the environmental PC board need to be removed from the housing ...

Page 7: ...ac cable connections at connector P7 on the other side of the environmental PC board If OK replace the PC board Connector P7 pin outs Pin Color Description 1 N A 24Vac 2 N A Common 3 N A 24Vac 3 Verify data is reaching the housing SENSORNET or RS 422 Press and hold switch SW2 on the environmental PC board and observe the yellow comm LED The LED should blink SensorNet or glow steadily RS 422 To ver...

Page 8: ...cture on the video monitor or dome movement 2 Detach the dome camera to access the environmental PC board Note Power to blowers comes from the dome Fans will not function with the dome removed CAUTION Touch the metal housing before handling the environmental PC board 3 Verify power is reaching the housing Press and hold switch SW2 and observe the green ac power LED it should glow steadily If not c...

Page 9: ...oard and reattach the dome If the fans still do not work replace the fan heater assembly Specifications Electrical combined dome and housing Input Voltage 24 to 30Vac 50 60 Hz NEC Class 2 Certified Limited Power Source Design Tolerance 20 to 36Vac 50 60 Hz Power Consumption 80W max Power On In Rush current 3A Surge Protection Video Series resistor of 3 9 ohms low capacitance Zener suppressor of 6 ...

Page 10: ...ery best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose NOTICE Th...

Reviews: