American Dynamics ADACSNETD Installation Manual Download Page 3

 

SENSORNET/MANCHESTER DISTRIBUTION PANEL 

8200-0712-01, REV. E 

INSTALLATION GUIDE 

3 of 5

 

Specifications 

Model Numbers 

ADACSNETD ................ No external power module 
ADACSNETDP..... Includes external power module 

Electrical 

Power Source......................External power module 

Transformer: 

North American (can power 3 units)..... 27VA 
International (can power 5 units).......... 45VA 

Input.........................12–30V, DC or AC, (50–60Hz) 
 

Certified Limited Power Source 

 

NEC Class 2 

 

Isolation not required 

Power Consumption ..........................................8VA 
Indicators: 

Power-On/Heartbeat ........................ Green LED 
Noise Detect.........................................Red LED 
Host A and B Receive Data .............Yellow LED 
Channels 1–16 Receive Data ..........Yellow LED 

Protection ................... Internal primary current fuse 
 Inrush 

limiting 

 DC 

Isolation 

Cable to transformer............................... 5m (16.5ft) 
 

18 AWG (0.823mm

2

), 3-conductor 

Input Connector...  Euro-style 3-pin removable plug 
 

5.06mm (0.2in.) terminal block 

Surge Protection.............. Transguard rated at 60V, 
 

250A, 1.5 Joules 

 

Gas discharge tube impulse rated at 10kA 

Design Tolerance: 

Input voltage minimum 11V DC or AC without 
drop out 
Input voltage >36V DC or AC may damage 
equipment 
Input frequency..................................... 47–63Hz 
Allowable drop out....................................150ms 

Power connector pin assignments: 

Pin 

Label 

Notes 

1 and 3 

12V – 30V 

AC/DC 

Connect 12–30V AC or 
DC power to these pins 
in any polarity  

2 Ground 

Used for surge 
protection and data line 
shields 

Surge Protection 

SensorNet/Manchester Ports 

Transient Voltage Suppressors (TVS): 

Break Down Voltage.........................7.6–9.3Vdc 
Peak Current.................................................40A 
Capacitance............................... 2000pf @ 1kHz 

Gas discharge tube impulse rated at:  

DC Break Down Voltage...........................90Vdc 
Insulation Resistance ........................ 10,000M

 

Capacitance........................................... 2pf Max 
8/20µs Impulse Discharge Current.............10kA 
Ten 8/20µs Impulses Discharge Current......5kA 

Isolation transformer coupled ..................2000Vrms 
PTC re-settable fuse protects transformer 

Mechanical 

Overall dimensions (LxWxD) ........... 481x87x34mm 
 

 

(18.9 x 3.4 x 1.3in.) 

Body length ....................................446mm (17.6in.) 
Weight........................................... 0.75kg (1.66 lbs) 
Mounting: EIA-310-D 19in. Electronic Racks (2 RU) 
 

IEC 60297-1 482.6mm Electronic Racks (2 RU) 

Compatibility 

Compatible with all versions of American Dynamics 
SpeedDomes, Manchester receiver drivers, 
J-Boxes, and control systems using SensorNet or 
Manchester protocols 

Environmental 

Operating Temperature ....................... -10° to 50°C 
 

(14° to 122°F) 

Storage Temperature........................... -40° to 70°C 
 

(-40° to 158°F) 

Relative Humidity ............ 0 to 95% non-condensing 
 

Summary of Contents for ADACSNETD

Page 1: ... Manchester multi point dome control communications and has 16 secondary device ports two connectors per port to accommodate home run dome wiring or multiple daisy chained connections to domes J boxes or other distribution panels Each of the ports has an LED that indicates data is being received Since Manchester communication is simplex one way communication received data is never present on the 1...

Page 2: ...o ground Ensure metal to metal contact Configuration Considerations SW1 Switch Settings Pos 0 Setting 1 Setting 1 50µs Turnaround Time 1 50µs Turnaround Time 1 2 Manchester SensorNet 3 Not used Not used 4 Not used Not used 5 Not used Not used 6 Not used Not used 7 LED Test Mode 2 Normal Operation 8 State Machine Test Mode 3 Normal Operation Notes 1 Turnaround time Normally SW1 position 1 is set to...

Page 3: ... equipment Input frequency 47 63Hz Allowable drop out 150ms Power connector pin assignments Pin Label Notes 1 and 3 12V 30V AC DC Connect 12 30V AC or DC power to these pins in any polarity 2 Ground Used for surge protection and data line shields Surge Protection SensorNet Manchester Ports Transient Voltage Suppressors TVS Break Down Voltage 7 6 9 3Vdc Peak Current 40A Capacitance 2000pf 1kHz Gas ...

Page 4: ...hield not used Pin 1 S Black wire Pin 2 S White wire Pin 3 Ground Shield used Terminating Resistor 120Ω switch selectable 120Ω switch selectable Physical Layer RS 485 transformer isolated 2 wire RS 485 transformer isolated 2 wire Data Encoding FM 0 Manchester Link Layer Framing SDLC HDLC Proprietary Link Layer Channel Bi directional half duplex Simplex Collision Avoidance Polling by primary host c...

Page 5: ...de the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose N...

Reviews: