SENSORNET/MANCHESTER DISTRIBUTION PANEL
8200-0712-01, REV. E
INSTALLATION GUIDE
3 of 5
Specifications
Model Numbers
ADACSNETD ................ No external power module
ADACSNETDP..... Includes external power module
Electrical
Power Source......................External power module
Transformer:
North American (can power 3 units)..... 27VA
International (can power 5 units).......... 45VA
Input.........................12–30V, DC or AC, (50–60Hz)
Certified Limited Power Source
NEC Class 2
Isolation not required
Power Consumption ..........................................8VA
Indicators:
Power-On/Heartbeat ........................ Green LED
Noise Detect.........................................Red LED
Host A and B Receive Data .............Yellow LED
Channels 1–16 Receive Data ..........Yellow LED
Protection ................... Internal primary current fuse
Inrush
limiting
DC
Isolation
Cable to transformer............................... 5m (16.5ft)
18 AWG (0.823mm
2
), 3-conductor
Input Connector... Euro-style 3-pin removable plug
5.06mm (0.2in.) terminal block
Surge Protection.............. Transguard rated at 60V,
250A, 1.5 Joules
Gas discharge tube impulse rated at 10kA
Design Tolerance:
Input voltage minimum 11V DC or AC without
drop out
Input voltage >36V DC or AC may damage
equipment
Input frequency..................................... 47–63Hz
Allowable drop out....................................150ms
Power connector pin assignments:
Pin
Label
Notes
1 and 3
12V – 30V
AC/DC
Connect 12–30V AC or
DC power to these pins
in any polarity
2 Ground
Used for surge
protection and data line
shields
Surge Protection
SensorNet/Manchester Ports
Transient Voltage Suppressors (TVS):
Break Down Voltage.........................7.6–9.3Vdc
Peak Current.................................................40A
Capacitance............................... 2000pf @ 1kHz
Gas discharge tube impulse rated at:
DC Break Down Voltage...........................90Vdc
Insulation Resistance ........................ 10,000M
Ω
Capacitance........................................... 2pf Max
8/20µs Impulse Discharge Current.............10kA
Ten 8/20µs Impulses Discharge Current......5kA
Isolation transformer coupled ..................2000Vrms
PTC re-settable fuse protects transformer
Mechanical
Overall dimensions (LxWxD) ........... 481x87x34mm
(18.9 x 3.4 x 1.3in.)
Body length ....................................446mm (17.6in.)
Weight........................................... 0.75kg (1.66 lbs)
Mounting: EIA-310-D 19in. Electronic Racks (2 RU)
IEC 60297-1 482.6mm Electronic Racks (2 RU)
Compatibility
Compatible with all versions of American Dynamics
SpeedDomes, Manchester receiver drivers,
J-Boxes, and control systems using SensorNet or
Manchester protocols
Environmental
Operating Temperature ....................... -10° to 50°C
(14° to 122°F)
Storage Temperature........................... -40° to 70°C
(-40° to 158°F)
Relative Humidity ............ 0 to 95% non-condensing