SENSORNET/MANCHESTER DISTRIBUTION PANEL
8200-0712-01, REV. E
INSTALLATION GUIDE
1 of 5
SensorNet/Manchester
Distribution Panel
Installation Guide
Figure 1. SensorNet/Manchester Distribution
Panel
ADACSNETD/ADACSNETDP
About this Guide
This installation guide explains how to install the
SensorNet/Manchester Distribution Panel.
If you need assistance...
Contact your Sales Representative.
Warning and Cautions
WARNING:
RISK OF ELECTRIC
SHOCK! Disconnect AC power to
the panel.
CAUTION-Electrostatic Sensitive
Device:
Follow proper handling
procedures to prevent component failure.
© 2008 Sensormatic Electronics Corp.
About the Product
The SensorNet/Manchester Distribution Panel
provides signal amplification for the SensorNet and
Manchester multi-point dome control
communications and has 16 secondary device
ports (two connectors per port) to accommodate
home-run dome wiring or multiple daisy-chained
connections to domes, J-boxes, or other
distribution panels.
Each of the ports has an LED that indicates data is
being received. Since Manchester communication
is simplex (one-way) communication, received data
is never present on the 16 secondary device ports;
therefore, the LEDs for ports 1, 2, and 3 will be
constantly ON with ports 4 through 16 OFF to
indicate the unit is in Manchester mode.
Figure 2. Distribution Panel components
Note:
The Noise Indicator may signal improper line
termination, line noise, packets cut short, or other
false carrier detection situations whenever a
too-short packet fragment is detected.
Output Data Connectors,
LEDS, and Switches
Power
Connecto
r
12–30V AC/DC
Noise Indicator
Host Connectors,
LEDs, and Switches
SW1 DIP Switches