background image

 

ADACSNET USB CONTROL MODULE 

8200-0310-01, REV. B 

INSTALLATION GUIDE 

3 of 6

 

Daisy-Chain/Backbone Network 

Use a daisy chain network if the cable is to be 
short, extended in the future, or when USB module 
and camera domes are in the same room. In a 
daisy chain, a separate cable connects every two 
adjacent devices along the chain. Daisy chaining 
makes it easy to add devices by extending the 
network from a nearby device. The USB module 
can connect anywhere along the cable. 

Use a backbone network if the cable is to be long 
and permanent. This network type operates the 
same as the daisy chain, but uncut wires may be 
more conductive and reliable. In a backbone, a 
single cable is used. Along the cable, 2.5cm (1in) 
sections are stripped, bent, and connected to each 
remote device. The USB module can connect 
anywhere along cable. 

The example below shows the USB module at end 
of a daisy chain or backbone network. The module 
and the last camera dome in the chain are 
terminated. 

Black box = USB module, T = Terminated 

 

 

The example below shows the

 USB module

 inserted 

in a daisy chain or backbone network. Camera domes 
on both ends of the chain are terminated; the

 module 

is not. 

Black box = USB module, T = Terminated 

 

 

 

When J-boxes are Used 

When using the USB control module with J-Boxes, 
consider the following rules (also refer to the 
following diagram): 

• 

Only use the AUX-to-HOST connection if the 
distance from the HOST to the last J-BOX is 
more than 1km (3300ft). Repeating is not 
needed when the USB module and the last J-
BOX are less than 1km (3300ft) apart. 

• 

From J-BOX 1 to J-BOX 2, use the HOST-to-
HOST connection only when the distance from 
the HOST and the last J-BOX is less than 1km 
(3300ft). 

• 

If using the J-BOX to amplify the signal, it is 
best to install it between 500 and 750m (1600-
2500ft). 

• 

Balance connection ports with domes (do not 
load on one side). 

SensorNet Cable 

SensorNet data cable.

 For plenum applications, 

use RPPS series cable. For non-plenum 
applications, use RPDS series cable.  

Composite cable.

 For plenum applications, use 

RPPCS series cable. For non-plenum applications, 
use RPNCS series cable. 

For further details, see 

Product Guide

 at: 

http://www.americandynamics.net/products_Catalog.asp

 

Note:

 In some environments, high noise on the 

network may limit cable distance to less than 1km 
(3300ft). 

Note.

 Sensormatic composite cable is 

recommended. This cable contains wires for power 
and video. If another cable is substituted, wire 
colors may be different. 

If shielded cable must be used, signals may rapidly 
decline as more devices are connected or its 
length increases. As a result, maximum length for 
shielded cable is reduced. For example, maximum 
length for Belden 8760 cable is 750m (2500ft) in 
ideal conditions (no noise). 

Not 

Terminated 

Summary of Contents for ADACSNET

Page 1: ...LED also blinks every time a data packet is sent to the camera dome Termination switch Termination is indicated by a resistor symbol near the switch See SensorNet Rules and Network Types in this document for when to set the switch The following diagram shows how to hook up the control module between the host Intellex or PC and a camera Software Installation for Non Intellex Systems If not connecti...

Page 2: ... repeaters in the path of any two camera domes A SensorNet line or branch cannot exceed 1km 3300ft Use signal repeaters only when exceeding the maximum distance or noise is an issue Signal levels for SensorNet compatible devices are from 0 3 5V 1 5V is recommended Network Types Star Network The star network allows you to relocate devices However this network is not recommended in high noise enviro...

Page 3: ... J Boxes consider the following rules also refer to the following diagram Only use the AUX to HOST connection if the distance from the HOST to the last J BOX is more than 1km 3300ft Repeating is not needed when the USB module and the last J BOX are less than 1km 3300ft apart From J BOX 1 to J BOX 2 use the HOST to HOST connection only when the distance from the HOST and the last J BOX is less than...

Page 4: ... J Box 1 J Box 2 Terminate the HOST when it is at the end of the line Balance connection ports with domes do not load on one side REPEATER REPEATER 91m 300ft 305m 1000ft Only use the AUX to HOST connection if the distance from the HOST to the last J BOX is more than 1km 3300ft From J BOX 1 to J BOX 2 use the HOST to HOST connection only when the distance from the HOST and the last J BOX is less th...

Page 5: ...ng FM 0 Link layer framing SDLC HDLC Link layer channel Bi directional half duplex Collision avoidance Polling by USB Module Application protocol Proprietary Network nodes Domes junction boxes secondary TouchTracker and SensorNet I O unit Power Input voltage 5 0Vdc 5 0 75W Internal voltage CPU Misc Support 3 3Vdc 5 Surge Protection SensorNet Gas discharge tube impulse rated at DC breakdown voltage...

Page 6: ...n customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose NOTICE The informat...

Reviews: