INSTALLATION AND SERVICE GUIDE
DeltaDome II Camera Dome
8000-2708-01, REV. B
9
Power-Up Routine
After power is connected to the dome, the dome
performs the following homing routine.
1. After a few seconds, the camera lens tilts up
into the housing and eyeball assembly.
2. The lens tilts downs until it looks at the floor.
3. Eyeball pans slowly.
4. Lens tilts up 90° (home position).
Once the lens is in its home position, you can
then use the controller to call up the camera
and control it.
Synchronizing Domes
To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to a 50Hz or 60Hz ac source. A V-phase
adjustment at the control console enables the
dome to sync to any line phase.
Diagnostic LEDs
If ADPTB standard base is used, LEDs in the
housing and eyeball assembly enable you to check
for power and data.
If ADIOB base with I/O board is used, LEDs on the
underside of the mounting base enable you to
check for power and data. If an RS422 network is
used, other LEDs on the board indicate that wiring
is correct, reversed, open, or grounded.