DESCRIPTION

The 2091 Megapower Code Converter receives high speed
code  from  a  1024  CPU  and  converts  the  code  into
Control Code which is used by all standard American
Dynamics receiver/drivers.   The 2091 also filters camera
switching information for monitors 1-8, when used with the
American Dynamics' 1631 Switcher Follower. 

The 2091 unit provides for 64 code outputs in four groups of
16.  The codes provide for controlling pan/tilt, lens, zoom,
focus, and iris; and auxiliaries at suitably-equipped camera
sites.

Control signals are received via the DATA LINE (older
systems used the term LAN).  Each of the four groups can
control a block of 64 cameras which is selectable via the dip
switches located next to each group on the rear panel.

If conversion to RS-232 is required, a DIP switch, located on
the main printed circuit board, is used to select the mode and
the baud rate.

FEATURES

The 2091 Code Converter has the following features:

SCREW TERMINAL WIRE CONNECTORS

LED INDICATORS FOR “GOOD” CODE

GREEN LED POWER INDICATOR

DIP SWITCH SELECTION FOR CAMERA GROUP
FOR CONTROL

BAUD RATE SELECTABLE RS-232 OUTPUT FOR
USE WITH MODEMS OR OTHER DEVICES

UNIVERSAL MOUNT CABINET

INSTALLATION

Power Sources

System models with the ‘AD’ prefix are configured for 120V,
50/60 Hz primary power source. Models with the ‘AD’
prefix and “-1” suffix are configured for a 230V, 50/60 Hz
primary power source, and are EU compliant. The 120 VAC
units are supplied with a pendant 3-wire cord and plug for
mating to the primary source outlet. The 230 VAC units are
supplied with a Euro-style IEC 320 type inlet. A suitable,
detachable cord should be connected between the IEC 320
inlet and the power source. The cord should conform to all
national and local use code requirements.

The 2091 Megapower Code Converter does not contain an
On/Off Switch.  The LED on the rear panel labeled Power, will
be lit when power is applied. Power consumption for the 2091
is approximately 7 watts.

Do not connect the equipment to the power source until
ready to “POWER UP”. The socket outlet shall located
near the equipment, and shall be readily accessible.

MOUNTING

The universal cabinet may be surface or full-rack mounted in
any convenient location with adequate ventilation.

As shipped, with the mounting ears flush with the front panel,
the 2091 can be mounted into the front of a standard 19” rack.

The "ears" can be un-screwed and mounted so they fit flush
with the rear panel.  This configuration provides for   mounting
into a rack equipped with mounting channels located on the
rear of the rack. The 2091 unit can also be mounted to the wall
by mounting the ears so they are either up or down with the top
and bottom covers of the unit.

Optimally, the 2091 should be located near the 1024
CPU and 1024 switching bays. 

Avoid heat sources or poorly ventilated racks. For proper
ventilation allow at least 3 feet (1m) from the rear of the racks
to any wall and 1 EIA rack height, 1 3/4”, between units.  The
2091 operates properly b32 degrees and +140 degrees
Fahrenheit (0 to +60 degrees Centigrade).

Operating power voltages must be held within 230V and 250V
for ‘AD/-1’ units.

DESCRIPTION

IF YOU ENCOUNTER ANY PROBLEMS

OPERATING THIS UNIT, OR NEED TECHNICAL

ASSISTANCE, CALL OUR SERVICE CENTER AT:

within the United States:  1-800-442-2225

outside the United States: (845) 624-7600

1

Safeguards must be taken to avoid unintentional operation

by employees and maintenance personnel working about

the premises, by falling objects, by customers, by

building vibration, and by similar causes.

Summary of Contents for AD2091

Page 1: ...e Converter converts data on the High Speed Data line to either Control Code used by American Dynamics Receiver Drivers or to RS 232 code which can be sent over networks and then converted to Control Code using a 1983 The Code Converter contains 64 Control Code outputs and indicators for both power and valid code that is being received from the Megapower CPUs via the data lines 2091 Megapower Code...

Page 2: ... is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATIC for its use nor for any infringements of other rights of third parties which may result from its use No license is granted by implications or otherwise under any patent or patent rights of SENSORMA...

Page 3: ...ved with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUARDS sheet 3 These Installation and Operating Instructions M M M MA A A AI I I IN N N NT T T TE E E EN N N NA A A AN N N NC C C CE E E E User maintenance of this unit is limited to external cleaning an...

Page 4: ......

Page 5: ...n 1 Features 1 Installation 1 Mounting 1 Connections Data Line Connection 2 Manchester Code Line Connections 2 Powering Up 3 Receivers 3 RS 232 Output 4 Baud Rate Selection 4 Filter Selection 4 Typical System Connections Appendix ...

Page 6: ......

Page 7: ...power source The cord should conform to all national and local use code requirements The 2091 Megapower Code Converter does not contain an On Off Switch The LED on the rear panel labeled Power will be lit when power is applied Power consumption for the 2091 is approximately 7 watts Do not connect the equipment to the power source until ready to POWER UP The socket outlet shall located near the equ...

Page 8: ...oup of four connectors are shipped with all switches in the the OFF position In the OFF state all receivers in a system will respond to cameras 1 64 If one 2091 is to control more than one block of cameras a block contains 64 cameras see Table 1 to set the dip switches Table 1 CODE GENERATOR DISTRIBUTION UNIT CAMERA SELECT GROUP 0 OFF 1 ON SELECT P T GROUP A B C D E F Cam 1 64 0 0 0 0 0 0 Cam 65 1...

Page 9: ...Class 2 low voltage circuits Where local codes permit installation conduit is not required Avoid installation near high voltage sources or other potential interference sources Code lines must be terminated in 120 ohms Check the final code controlled unit on each code line and if a 120 ohm termination is not present add one Up to five Control Code control devices may be daisy chained on a single co...

Page 10: ...x as diagramed in Figure 5 Now you can POWER UP the unit Table 3 DIP Switch S5 Baud Rate Settings Switch Position Switch Position set to ON set to OFF Baud Rate 8 1 2 3 4 5 6 7 1200 7 1 2 3 4 5 6 8 2400 6 1 2 3 4 5 7 8 4800 5 1 2 3 4 6 7 8 9600 Note Positions 1 4 on the 8 position dip switch are always set to OFF Except for Filter Selection as described below If any of the above baud rate DIP swit...

Page 11: ...APPENDIX ...

Page 12: ......

Page 13: ... W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S DATA LINE IN OUT IN OUT 1 2 CODE SELECT 1 2 PWR HIGH SPEED DATA LINE FROM CPU HIGH SPEED DATA OUT TO ADDITIONAL 2...

Page 14: ......

Page 15: ...cations Safety EN 60950 1992 EMC EN 50130 4 1995 EN 55022 1994 Class B EN 61000 3 2 1995 EN 61000 3 3 1995 EN 61000 4 2 1995 EN 61000 4 3 1996 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 61000 4 11 1994 Supplementary Information The products herewith comply with the requirements of the Low Voltage Directive 73 23 EEC as amended by 93 68 EEC and the EMC Directive 89 339 EEC as amended ...

Page 16: ...nting Surface Mount or Rack Mount Weight 7 0 lbs Finish Shadow Gray Size 17 W x 7 75 D x 3 5 H Sensormatic Video Systems Division One Blue Hill Plaza Pearl River New York 10965 845 624 7600 Technical Support Center 1 800 442 2225 FAX 845 624 7685 8000 1825 01 Revision A December 2000 Printed in USA ...

Reviews: