PROBLEM
CHECKLIST
Unit does not respond to
power-up tests
Check that 24VAC is connected to pins 3 & 5 of 7-pin connector
After power on tests, unit does
not respond to joystick commands
Check that BLACK data wire is connected to pin 7 of 7-pin connector and
WHITE data wire is connected to pin 5 of 7-pin connector
Check that address of dome is properly set to match camera ID number
Check that dipswitch position 1 is set to match camera type
ON = color OFF = monochrome
Cannot control lens function ( Zoom )
Check that dipswitch position 3 is set to the OFF position
Auto-Iris not working
Check that dipswitch position 4 is set to the OFF position
TROUBLESHOOTING
A11