American Dynamics AD1202 Installation And Operating Instructions Manual Download Page 9

EXTERNAL Connector

A 24-pin connector on the rear panel, labeled EXTERNAL,
provides pins for external alarm inputs and control signals.  A
mating 24-pin plug-in connector with flying leads is provided.

EXTERNAL Connector Pinouts

Pin

Function

Pin

Function

1

Channel SEL 1

13

Alarm Input 3

2

Channel SEL 2

14

Alarm Input 4

3

Channel SEL 3

15

Alarm Out

4

Channel SEL 4

16

Ground

5

Code Black (1)

17

BIN IN bit 0

6

Code White (1)

18

BIN IN bit 1

7

Code Shield (1)

19

BIN IN bit 2

8

Code Black (2)

20

BIN IN bit 3

9

Code White (2)

21

External Unit

10

Code Shield (2)

22

Ground

11

Alarm Input 1

23

Code Select

12

Alarm Input 2

24

Ground

From the rear of the AD1202, pin 1 is the bottom-right, pin 2 is
the top-right, and pin 24 is the top-left of the connector.

ALARM INPUTS

The EXTERNAL connector provides four Alarm Input pins
(pins 11 - 14) for external alarm contacts, one for each
camera input.  The Alarm Input number refers to the
associated camera input number.  The AD1202 responds to
normally open (NO) contact closures from external alarm
devices (see page 9 for Alarm Response).

1. Connect the external alarm contact signal line to the

appropriate Alarm Input (pin 11 - 14).

2. Connect the remaining side of each alarm contact to

Ground (pin 16, 22, or 24).

Alarm contact closures to ground must have a resistance of
500 ohms or less; alarm opens must have a resistance of
100,000 ohms or more.

Note: If alarm contacts are installed and the AD1202 is

connected to a switcher, connect each alarm contact
in parallel to both the switcher and the AD1202
alarm inputs.  See page C-5 for an illustration of
alarm connections to both the AD1202 and a
switcher.

ALARM OUTPUT

The AD1202 provides an open collector output pulse on pin
15, Alarm Out, when an alarm input is received.  The pulse
is held active until the alarm input clears, with a minimum of
five seconds duration.  This pulse can be used to activate an
external device such as a VCR.

1. Connect Alarm Out (pin 15) to the external device.

2. Connect the remaining side of the device control signal

to Ground (pin 16, 22, or 24).

CAMERA ADDRESS INPUT

The binary input, BIN IN (pins 17 - 20), accepts a binary
camera number input from an MCS-compatible AD
switcher.  These pins allow the AD1202 to operate as a
controller follower, permitting external selection of a camera
by the connected switcher (see Camera Selection, page 6).

Connect the camera binary address pins from the switcher to
the AD1202 BIN IN pins.

1. Connect the switcher camera address bit 0 to the BIN IN

bit 0 (pin 17).

2. Connect the switcher camera address bit 1 to the BIN IN

bit 1 (pin 18).

3. Connect the switcher camera address bit 2 to the BIN

IN bit 2 (pin 19).

4. Connect the switcher camera address bit 3 to the BIN

IN bit 3 (pin 20).

5. Connect a ground pin from the switcher to Ground (pin

16, 22, or 24).

CHANNEL SELECT OUTPUTS

The Channel SEL pins (pins 1 - 4) provide individual logic
level outputs for each camera channel.  Each Channel SEL
pin is active (logic high) when the respective camera channel
is selected (see Camera Selection, page 6).  These signals
can be used to control an external device.

1. Connect the applicable Channel SEL output (pin 1 - 4)

to the device desired.

2. Connect the remaining side of the device control signal

to Ground (pin 16, 22, or 24).

AD1202

CONNECTIONS

3

Use NEC Class 2 wiring only for all EXTERNAL
connector pin connections. The wiring should also
conform to all local codes.

!

Note

If any address bit inputs are not provided, connect

those AD1202 pins to Ground (pin 16,22, or 24).

Summary of Contents for AD1202

Page 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Page 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Page 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Page 4: ......

Page 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Page 6: ......

Page 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Page 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Page 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Page 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Page 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Page 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Page 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Page 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Page 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Page 16: ......

Page 17: ...Appendix...

Page 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Page 19: ...Typical System Connections...

Page 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Page 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Page 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Page 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Page 24: ......

Page 25: ...Index...

Page 26: ......

Page 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Page 28: ......

Page 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Page 30: ......

Page 31: ...tonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type MCS Coax Controller Model Number ADS1202X comply with the EMC Standards EN55022 Class B EN50082 1 and also com...

Page 32: ...rol Code outputs Alarm Inputs Four alarm contact closures Normally Open one input per camera Alarm Output One alarm output TTL open collector pulse Mounting Desktop or Rack mount with AD2117 21 kit Di...

Reviews: