DESCRIPTION

The AD1202 MCS Coax Controller is a compact Pan/Tilt,
Lens, Preset Scene, and Auxiliary controller for four color or
monochrome cameras.  The AD1202 provides coax control of
four cameras via the video line connection to the camera site.
Additionally, AD Manchester Control Code outputs are
available for control of non-coax camera Receivers.

Each camera can be individually selected and controlled from
the AD1202 front panel.  The selected camera’s video input is
displayed via the rear panel Monitor output.  Pushbutton
control is provided for camera pan/tilt, lens zoom/focus/iris,
preset scene, and auxiliary functions.

The AD1202 responds to external alarm contact closures by
automatically calling the alarmed camera to the monitor output
and calling preset 1 of that alarmed input.  Separate alarm
inputs are provided for each camera input.  The AD1202 also
provides a pulse output when an alarm is received at any of the
four alarm inputs.  This pulse can be used to activate an
external device such as a VCR.

Camera preset scenes at suitably equipped camera sites can be
controlled by the AD1202, using AD1640 and AD1680 Series
Receivers.  The AD1202 can program and recall any of the
first four presets (1 - 4) for one of these Receivers.

Looping video outputs allow the AD1202 to operate as a
control follower with MCS-compatible American Dynamics
switchers.  The AD1202 can respond to camera selections
made by the switcher to allow coax control of the requested
camera.  The AD1202 can be programmed to control any four
cameras of the switcher.  Four AD1202 Controllers can be
cascaded to a single MCS switcher to control sixteen cameras.

A security lockout feature disables front panel programming
controls.  This capability prevents inadvertent changes to
camera programming.

A built-in test procedure provides verification of AD1202 front
panel controls and indicators.

FEATURES

Individual control of four cameras via coax video line or
separate AD Manchester Control Code line

Selectable coax control code for variable speed (Enhanced
Code) or fixed speed (Standard Code).

Dual-speed pan/tilt control, full lens zoom, focus, and iris
control, plus control of four auxiliaries

Monitor output of selected or alarmed camera video input

Four preset scenes programmable for each camera

Separate alarm input for each camera

Automatic camera preset scene callup and alarm pulse
output on alarm receipt

Remote camera selection from MCS-compatible AD
switchers

Cascade multiple Coax Controllers to a single switcher

Front panel security lockout

INSTALLATION

This installation should be made by qualified service personnel
and should conform to all local codes.  Safeguards must be
taken to avoid unintentional operation by employees and
personnel working about the premises, by falling objects, by
customers, by building vibration, and by similar causes.

Mounting

The AD1202 Coax Controller is supplied as a desktop unit.
Locate in a convenient position, near the associated video
switcher (if connected as a switcher controller) and the video
monitor connected to the unit.

For rack-mounting, use American Dynamics rack-mount kit,
model AD2117/21.  The AD1202 is a half-rack width unit.
Two half-rack units may be mounted in a single 19” by 1-3/4”
rack.  Install with a minimum of 1 3/4-inch clearance between
rack units.  Avoid heat sources or poorly ventilated racks.
Mount in a convenient location near the associated monitor
and switcher.

AD1202

DESCRIPTION, FEATURES, and INSTALLATION

1

MCS

1

2

3

4

CLOSE

OPEN

IRIS

FAR

NEAR

FOCUS

WIDE

TELE

ZOOM

PRESET

CALL

SET

AUX

OFF

ON

SEL

PGM

Figure 1 - AD1202 Coax Controller

Summary of Contents for AD1202

Page 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Page 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Page 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Page 4: ......

Page 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Page 6: ......

Page 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Page 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Page 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Page 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Page 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Page 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Page 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Page 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Page 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Page 16: ......

Page 17: ...Appendix...

Page 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Page 19: ...Typical System Connections...

Page 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Page 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Page 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Page 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Page 24: ......

Page 25: ...Index...

Page 26: ......

Page 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Page 28: ......

Page 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Page 30: ......

Page 31: ...tonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type MCS Coax Controller Model Number ADS1202X comply with the EMC Standards EN55022 Class B EN50082 1 and also com...

Page 32: ...rol Code outputs Alarm Inputs Four alarm contact closures Normally Open one input per camera Alarm Output One alarm output TTL open collector pulse Mounting Desktop or Rack mount with AD2117 21 kit Di...