American Dynamics AD1020-1541 Installation And Operating Instructions Manual Download Page 6

INSTALLATION AND
OPERATING INSTRUCTIONS

1020 SERIES 30/60-WATT LED INFARED ILLUMINATOR

8000-1794-01, REV. A

6

Secondary Connections

  Pass the low-voltage wiring through the

previously installed 3/8-inch bushing (Figure 4).

  Open a ferrite clamp and route the wires

through it, then close the clamp.

  Secure the ferrite clamp to the inside of the

enclosure by means of the double-sided tape
provided.

  Tighten the bushing.

If using the 2-wire system, leave the two
jumpers in place between –S/-V and +S/+V. If
using the 4-wire system, remove the two
jumpers (Figure 6).

Note: 

Terminal #4 on the terminal strip is not

used.

  Connect Output –S (if used) to terminal #5

(Figure 4 and Figure 7).

  Connect Output –V to terminal #6.

  Connect V to terminal #7.

  Connect S to terminal #8.

Figure 6.  Power supply terminal strip

+S      +V       -V       -S       FG       L         N

+S      +V         -V       -S

Power Supply Operation

120Vac/230Vac Operation

The 1040-3060PSA Power Supply is designed to
operate on 120Vac to 230Vac, 50/60Hz without
the need for adjustment or jumpers.

1040-3060PSA Power Supply Output
Voltage

Before connecting the 1040-3060PSA Power
Supply to the Illuminator, verify and, if necessary,
adjust the power supply output voltage to 13.5
±0.1Vdc.

Measuring the 1040-3060PSA
Output Voltage

  Verify jumper clip are installed from +S to +V

and from –S to –V on the terminal strip (Figure
6)
.

  Connect a DC voltmeter across the +S/+V and

the –S/–V terminals.

  Connect the proper input supply voltage

(120Vac or 230Vac) to the input terminals.

  Confirm a reading of 13.5 ±0.1Vdc. If

necessary, adjust the Voltage Adjustment
Potentiometer VR51.

Adjusting the 1040-3060PSA Output
Voltage

The Voltage Adjustment Potentiometer, labeled
VR51, is mounted on the printed circuit board
(Figure 6).

Using a suitable screwdriver, carefully adjust VR51
to obtain 13.5 ±0.1Vdc, measured across the
output terminals (+V and –V).

Caution:

 Output voltages over 15Vdc activate the

1040-3060 over-voltage protection circuit. Reset
the circuit by disconnecting the source voltage
from the 1040-3060 for a minimum of 60 seconds.

Two-Wire Connections

Two-wire connections are for power supplies that
do not have remote sensing capabilities (see
Power Supply Selection, page 2). Two-wire
connections are acceptable for installations
requiring short wire lengths between the power
supply and the Illuminator, or where the use of
large-gauge wiring is acceptable.

Notes:

  Long wire lengths induce voltage drops

between the power supply and the Illuminator,
resulting in reduced IR output and a loss of
viewing range.

  The 1020 Series Illuminators require a stable

13.5 ±0.1Vdc input to maintain peak IR
wavelength emission (see Figure 9.  LED
emissions, page 10.

Table 1 (for 30-watt Illuminators) and Table 2 (for
60-watt Illuminators) list the recommended AWG
wire size for the distance between the power
supply and the Illuminator when using 2-wire
connections.

Jumper Clips

Terminal Strip

5606-0024-01
Power Supply

Voltage

Adjustment

Potentiometer,

VR51

Summary of Contents for AD1020-1541

Page 1: ...a license for use on a single system Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable However no responsibility is assumed by AMERICAN DYNAMICS for its use nor for an...

Page 2: ...oduct for service Do not attempt to service this product yourself Opening or removing covers may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel Descriptio...

Page 3: ...Before installation become familiar with all the special features and warnings associated with this equipment Once installation is complete store this document in a safe convenient location for futur...

Page 4: ...ponents B C and D of the liquid tight hub Figure 3 into an appropriate pass through Note Hub B fits through the O ring D on the outside of the enclosure and is secured by nut C on the inside of the en...

Page 5: ...osure by means of the double sided tape provided Tighten the bushing Caution If necessary trim the MOV surge suppressor leads to keep them as short as possible After the leads are connected to the ter...

Page 6: ...he S V terminals Connect the proper input supply voltage 120Vac or 230Vac to the input terminals Confirm a reading of 13 5 0 1Vdc If necessary adjust the Voltage Adjustment Potentiometer VR51 Adjustin...

Page 7: ...0 3060PSA Power Supply uses remote sensing to maintain a constant voltage at the Illuminator A 4 wire configuration between the power supply and the Illuminator maintains the correct load voltage over...

Page 8: ...0 watt illuminator AWG Distance 12 0m 30 5m 0 100 14 0m 22 9m 0 75 16 0m 15 2m 0 50 Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Lamp does not come on No 13 5 Vdc to Lamp Check 120 Vac or 230 Vac s...

Page 9: ...020 SERIES 30 60 WATT LED INFARED ILLUMINATOR 8000 1794 01 REV A 9 Dimensions Figure 8 1020 series Illuminator dimensions 30 60 Watt model 65mm 2 56 182mm 7 17 127mm 5 0 2mm 08 21mm 83 6mm threaded ho...

Page 10: ...range 22m 72ft 20m 66ft 20m 66ft 55m 180ft 42m 138ft 35m 115ft ELECTRICAL Operating Voltage 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc Current Amps 2 5A 2 5A 2 5A 4 6A 4 6A 4 6A ALL UNITS Service...

Page 11: ...sible for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition Other Declarations WARRANTY DISCLAIMER Sensormatic Electronics Corporation make...